Electrical data 23, Electrical data – Miele DA220-4 User Manual

Page 23

Advertising
background image

All electrical work should be
performed by a qualified electrician
in strict accordance with national
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer
cannot be held responsible for
unauthorized work.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.

^ Verify that the voltage, load and

circuit rating information found on the
data plate (located behind the
grease filter), match the household
electrical supply before installing the
hood.

If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or contact Miele’s
Technical Service Department. See
back cover for contact information.

WARNING:
THIS APPLIANCE MUST BE
GROUNDED

Important

The hood must be hard wired
accordingly:

Black/Red wire:. . . . connect to L1 (live)

White wire: . . . . . connect to N (neutral)

Green wire: . . connect to GND (ground)

Maximum load
DA 220-3 . . . . . . . . . . . . . . . . . . . 430 W

Lighting . . . . . . . . . . . . . . . . . . 4 x 20 W

Voltage . . . . . . . . . . . . . . . . . . . . . 120 V

Frequency . . . . . . . . . . . . . . . . . . 60 Hz

Circuit rating. . . . . . . . . . . . . . . . . . 15 A