Warning, Heater selection chart, Caution – Marley Engineered Products RK Series User Manual

Page 2

Advertising
background image

LIMITED WARRANTY

All products manufactured by Marley Engineered Products are warranted
against defects in workmanship and materials for one year from date of instal-
lation, except heating elements which are warranted against defects in work-
manship and materials for five years from date of installation. This warranty
does not apply to damage from accident, misuse, or alteration; nor where the
connected voltage is more than 5% above the nameplate voltage; nor to equip-
ment improperly installed or wired or maintained in violation of the product’s
installation instructions. All claims for warranty work must be accompanied by
proof of the date of installation.

The customer shall be responsible for all costs incurred in the removal or rein-
stallation of products, including labor costs, and shipping costs incurred to return
products to Marley Engineered Products Service Center.Within the limitations of
this warranty, inoperative units should be returned to the nearest Marley autho-
rized service center or the Marley Engineered Products Service Center, and we
will repair or replace, at our option, at no charge to you with return freight paid
by Marley. It is agreed that such repair or replacement is the exclusive remedy
available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH
EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DIS-
CLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY
ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL
DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED
UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do not allow the exclusion or limitation of incidental or consequen-
tial damages, so the above exclusion or limitation may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.

For the address of your nearest authorized service center, contact Marley
Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise
returned to the factory must be accompanied by a return authorization and ser-
vice identification tag, both available from Marley Engineered Products. When
requesting return authorization, include all catalog numbers shown on the prod-
ucts.

INSTALLATION OF ELEMENTS

1. Place heater on flat surface and remove both wiring compart-

ment covers.

2. Remove the outside hex nut from both ends of the element.
3. Place the element in the “L” shaped slots in the heater housing.
4. Install ring terminal on factory installed wire assemblies on the

threaded studs on both sides of element. See Fig. 1.

5. Replace hex nut and secure
6. Replace wiring compartment covers.
APPLICATION LIMITATION AND PRECAUTIONS

Hazardous Atmosphere - These heaters are not suitable for
use in hazardous locations.

Indoor Use Only

• Ceiling Mount Only - Do not mount to walls.

Maintain at least 5’ (1.5 m) in radiant path between bottom of
heater and combustible material.

Corrosive Atmospheres - The high quality finish and steel

internal sheet metal parts will give excellent service under most
operation conditions, including coastal salt air and most indus-
trial atmospheres. However, the finish is not intended for salt
spay exposure in marine applications or highly corrosive green-
house, swimming pool, chemical storage or industrial atmos-
pheres.

The mounting structure and anchoring hardware must be

capable of reliably supporting the total weight of the heater and
all accessories.

INSTALLATION OF HEATER

1. Cut suspension chain (approved) to desired mounting length.
2. Attach chain to heater with “S” hooks provided. Heater must

be mounted so that element is horizontal

3. Tilt heater (if desired) by adjusting chains as shown in Fig 2.

WIRING

1. Supply wiring coming to heater must be rated at least 90

degrees C. USE COPPER WIRING ONLY.

2. Rough-in Wiring. Run supply wiring to the heater location

(Check heater nameplate and element for proper supply volt-
age.) Check the amperage of the heater (refer to nameplate on
heater) and verify the supply wiring is properly fused.

3. Wire heaters as shown in Fig. 3.

Fig. 1

Fig. 2

WARNING

SUPPLY WIRING MUST BE SIZED FOR MAXIMUM WATTAGE
OF HEATER WITH QUARTZ TUBE.

!

Fig. 3

HEATER SELECTION CHART

DO NOT HANDLE QUARTZ LAMP OR QUARTZ TUBE HEATING ELEMENTS
WITH BARE HANDS AS SALT IN PERSPIRATION MAY DETERIORATE THE
QUARTZ.

CAUTION

!

Dimensions

Model No.

Volts Watts

Reflective

Height

Width

Length

Wt.

Angle

in. (mm)

in. (mm) in. (mm) lb (kg.)

RK41512

120

1500

RK42020

208

2000

RK42024

240

2000

RK42027

277

2000

46 (1168)

9 (4.1)

RK42034

347

2000

RK42048

380

2000

RK42060

600

2000

60 (Sym)

3.375 (86)

5.5(140)

RK53020

208

RK53024

240

RK53027

277

3000

RK53034

347

57 (1448)

11 (5.0)

RK53048

480

RK53060

600

HOW TO ORDER REPAIR PARTS

In order to obtain any needed repair or replacement parts, warranty service or

technical information, please contact Marley Engineered Products Service Center toll-
free by calling 1-800-642-HEAT.

When ordering repair parts, always give the information listed as follows:

1. The Part Number
2. The Model Number
3. The Part Description
4. Date of Manufacture

Part No. 5200-2395-000

PPD 024

8/00

SPX Corporation
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA

2

OPTIONAL MECHANICAL ACCESSORIES

Quartz Tube

Ring Terminal

Hex Nut

Model No.

Description

Carton

Wt.

Qty.

lbs (gr.)

WG46

Wire Guard

1

1 (454)

WG57

1.5 (680)

RP-WMB

Wall Mounting Bracket

1

2 (907)

Advertising