2.4.1.3 Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting

For a threaded tank sender mounting hole, first thread the adapter into the tank opening and
tighten to a torque of 3-5 ft-lbs (4.1-6.8 N·m).

Next, place the TLM150 gasket over the adapter so that the bolt holes on the gasket line up
with the bolt holes on the adapter (WARNING – the gasket must be properly aligned; it only fits
one way). Place the TLM150 sensor component on top of the adapter so that the bolt holes on
the TLM150 sensor component line up with the bolt holes on the adapter.

Place the included mounting screws through the bolt holes on the TLM150 sensor component,
and thread them into the adapter, tightening them to a torque of 10-15 in-lbs (1.1-1.7 N·m). Do
not use threadlocking compounds containing methacrylate ester, such as Loctite Red (271), as
they will cause stress cracking of the plastic enclosure.

TLM150 Interface Component

Threaded Tank Fitting

Threaded Adapter

TLM150 Gasket

TLM150 Sensor Component

Mounting Screws (x5)

Figure 4 – TLM150 Mounting With Threaded Adapter