Microboards net configuration, Configuration options, Basic configuration – MicroBoards Technology LightScribe Series User Manual

Page 8

Advertising
background image

DVD Premium Pro LightScribe Series MICROBOARDS TECHNOLOGY, LLC

8

NET MASTER
YES: SET

MASTER

NET MASTER
NO:

STANDALONE

Master Display alternates
between these messages

NET SLAVE X
NO:

STANDALONE

Final tower in chain

Microboards NET Configuration

The Microboards NET configuration allows you to connect multiple 10-drive tower duplicators.
They can function together as a single duplicator with 10 drives per tower for ultra high-quantity
production, or can operate independently as stand-alone duplicators, each copying from a
different master.
It does not matter which tower is set as the Master; the only restriction is that one tower of the
chain must have the NET cable connected to the Out port only. The last tower in the chain will
only use the In port.

Configuration Options

To set the Multi-Tower configuration, turn on power
to all of the connected towers and wait for the
configuration options to be displayed, as shown to
the right.
The exact display message and configuration
options on each tower will depend on the location of
that tower in the chain.

Once the configuration has been selected, you must
either power cycle all towers or run the Net Reboot
on all Master towers to change the configuration.
The display of any Master or Stand-Alone tower will initially read COPY

START

when it is ready for duplication. The control panel on Slave towers

is disabled.

Basic Configuration

The most basic configuration would be to set the first tower as the Master with the remaining
towers as Slaves. For this configuration, you would only need to press the YES button on the
Master tower when the configuration options are showing.

The result with a six-tower configuration is shown above. Only the reader and hard drive on the
NET Master will be available as source drives.

Net Reboot and Basic Configuration
To run the Net Reboot, press either the ▲or ▼ button until the display reads SETUP. Press the
YES

button, then press either the ▲or ▼ button until the display reads NET REBOOT. Press

YES

and all towers will reboot.

NET

Master

NET

Slave 1

NET

Slave 2

NET

Slave 3

NET

Slave 4

NET

Slave 5

NET SLAVE 1
YES: SET

MASTER

NET SLAVE 1
NO: STANDALONE

First Slave Display, additional Slave

towers show Slave number sequentially

Advertising