Portable gasoline generators, Operation, Continued – Master Lock HWI3000 User Manual

Page 12: Prestart, Starting

Advertising
background image

12

105202

PORTABLE GASOLINE GENERATORS

R

Choke Lever (Open Position)

Figure 21 - Choke Lever Opened (Model
MGH7000D Shown)

HONDA

OFF

ON

START

ENGINE SW

CIRCUIT
BREAKER

ON/push OFF

Figure 19 - Engine Switch In ON Position
(All Models Except MGH5000DIE,
MGH7000D, and MGH10000A)

Figure 20 - Engine Switch (Models
MGH5000DIE, MGH7000D, MGH7000DI,
and MGH10000A Only)

4.

Start the engine.

A. Recoil Starter

Turn engine switch to the ON position
(see Figures 19 and 20). Remove slack
from starter rope by lightly pulling
starter grip. Next, pull starter rope
briskly.

IMPORTANT:

Do not let starter grip

snap back against engine. Return it gen-
tly. This will prevent damage to starter.

Note:

If engine does not start, check

the oil in the crankcase. Add oil as nec-
essary. Be sure engine is on a level sur-
face. See Oil Alert System, page 6.

B. Electric Starter (Models
MGH5000DIE, MGH7000D,
MGH7000DI, and MGH10000A Only)

Turn the engine switch to the START
position (see Figure 20). Hold it there
until engine starts. When engine starts,
let switch return to the ON position.

IMPORTANT:

Do not use electric

starter more than five seconds. Starter
motor damage may occur. If engine
fails to start, release the switch and wait
ten seconds. After ten seconds, try start-
ing again.

Note

: If engine does not start, check

the oil in the crankcase. Add oil as nec-
essary. Be sure engine is on a level sur-
face. See Oil Alert System, page 6.

5.

As engine warms up, slowly move
choke lever fully to the right (see Fig-
ure 21). This opens the choke. On
Model MGH10000A, the choke will
automatically open.

ENGINE SW

ON

OFF

Engine
Switch

OPERATION

Continued

PRESTART

Operate generator on a firm, dry, and clean
surface. The surface must be level. Protect
generator from heavy dust, sand, dirt, rain,
or snow. Do not locate generator near stand-
ing water and snow. Make sure area is well-
vented.

WARNING: Only responsible

adults should use generator.
Never let anyone operate genera-
tor without proper instructions.

Note:

If oil level is too low, oil alert system

will keep engine from starting (see Oil Alert
System
, page 6). Make sure oil level is full
before starting. See Engine Oil, page 7.

Before starting the engine, disconnect all
electric loads from generator.

STARTING

IMPORTANT:

The engine speed is preset.

The throttle is locked in preset position. Do
not adjust throttle. Preset position lets en-
gine run at 3600 RPM under load. The
engine must maintain 3600 RPM for gen-
erator to create correct voltage. Running
engine at lower speeds will damage genera-
tor and powered items.

IMPORTANT:

Never start generator with

electrical loads connected. Start engine be-
fore adding electrical loads.

1.

Make sure gasoline tank is full. See
Fuel, page 7 for fuel information.

2.

Move fuel valve lever to the ON posi-
tion (see Figure 17).

3.

Move choke lever fully to the left (see
Figure 17) or pull choke button out
(Model MGH10000A only, see Figure
18). This closes the choke.

Note:

You may not need to close choke

if engine is warm or air temperature is
high.

Fuel Valve Lever (ON Position)

Choke Lever (Closed Position)

Figure 17 - Fuel Valve Lever On, Choke
Lever Closed (Model MGH4000D Shown)

Figure 18 - Choke Button Closed (Model
MGH10000A Only)

Choke Button
Pulled Out
(Closed Position)