Generator features, Continued – Master Lock MGY5000 User Manual

Page 9

Advertising
background image

9

CHARGE

OFF

OIL

Battery
Discharge
Lamp

Oil Alert
Lamp

Figure 2 - Battery Discharge Lamp and Oil Alert Lamp Location

Continued

GENERATOR

FEATURES

Continued

FULL POWER SELECTOR SWITCH

The full power selector switch is on the control panel. The switch has two posi-
tions: 120 VOLT ONLY, and 120/240 VOLT.

120 VOLT ONLY:

This position sends full power to the 120V receptacles only.

240V power is not available. Use this position when powering 120V items only.

120/240 VOLT:

This position sends full power to the 120/240V receptacle. It also

powers the 120V receptacles at reduced wattage capacity.

IMPORTANT:

Do not move the full power selector switch while powering

electrical items. Unplug all items before moving switch. Failure to do so can
damage switch.

BATTERY DISCHARGE LAMP

The battery discharge lamp (see Figure 2, above) will light if battery charger is not
operating while engine is running. If this happens, the battery will not charge and
will eventually run down. Have battery charging circuit repaired by authorized
service person.

120V

ONLY

120

240V

FULL POWER

SELECTOR

120V

ONLY

120

240V

FULL POWER

SELECTOR

120 VOLT ONLY

Position

120/240 VOLT

Position

Figure 3 - Full Power Selector Switch