5-3. 14-Pin Plug PLG12 Information

Pin*

Pin Information

A

24 volts ac with respect to socket G.

A

J

K

B

Contact closure to A completes 24 volts ac contactor control circuit.

A

J

B

K

I

L

G

Circuit common for 24 volts ac circuit.

C

L

N

H

D

M

G

C

+10 volts dc input from power source to wire feeder with respect to socket D.

D

M

G

E

F

D

Remote control circuit common.

E

F

E

0 to +10 volts dc output signal from wire feeder to power source with respect to socket D.

H

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

F

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

*The remaining pins are not used.

5-4. Gun Recommendation Table

Process

Gun

GMAW − Hard or Cored Wires

Q-Series Guns: 300, 400, 500,

And 600 Amp.

FCAW − Self-Shielding Wires

FC-1260 Or FC-1150

5-5. Wire Type, Size, And Feed Speed Capability Table

Motor Speed

Wire Type

Wire Size

Feed Speed Capability

Standard

All

.023 To 5/64 in (0.6 To 2 mm)

50 To 1400 ipm (1.3 To 35.6 mpm)

Low

All

.023 To 1/8 in (0.6 To 3.2 mm)

20 To 400 ipm (0.5 To 10.1 mpm)

5-6. Installing Drive Rolls

804 187-A

1

Pressure Assembly Door

2

Drive Roll

3

Ejector Button

4

Drive Roll Carrier

Installation
Open pressure assembly door.
Align drive roll slots with three lobes

on drive roll carrier.
Insert drive roll onto carrier. Drive

roll will snap into place.
Removal

.

Must remove PD wire guide be-
fore removing lower drive rolls.

Lift up drive roll swing arm and

press ejector button in middle of

drive roll carrier.

.

If ejector button does not re-
turn to normal position (out),

install a drive roll and ejector

button will pop out.

1

2

4

3