Str/cvr series woodburning fireplaces, Installing the chimney system, Installing the firestop spacer in the ceiling hole – Majestic CVR42 User Manual

Page 12: Proper firestop spacer installation

Advertising
background image

12

STR/CVR Series Woodburning Fireplaces

7412961

Installing the Chimney System

Start by attaching the first chimney section to the collar
on top of the fireplace.
Install the pipe as pictured in Figure 16. When you
get a good lock, you will hear the pipe clearly snap
together. Once sections are snap-locked in place, it is
extremely difficult to get them apart. Make sure the
pipe is firmly snapped and locked together as each
pipe section is mounted.
When installing elbows, only outer pipe will snap-
lock. Middle pipes simply slide into position. Be sure
to always attach straps on upper elbow to a structural
framing member. (Fig. 17)
Continue installing the pipe as required until pipe is
installed up through the ceiling. At this point, you must
install a firestop spacer. Refer to Figure 18 for appropri-
ate spacer orientation.

Installing the Firestop Spacer

in the Ceiling Hole

A firestop spacer is used to keep pipe spaced properly
and required for safety.
Nail the firestop spacer (at each corner) to the framing
members of the ceiling hole. NOTE: A firestop spacer
is not required at the roof.
Hole sizes listed in Figure 12 for angled firestop spac-
ers provide minimum required air space to chimney
pipe for ceiling thickness up to 8" (203mm). When
combined thickness of ceiling material, ceiling joists
and flooring material exceeds 8" (203mm), adjustments
must be made in framing to assure that minimum air
spaces to chimney are maintained.

Proper Firestop Spacer Installation

Figure 18 shows different installation procedures for
both an area that is an attic and an area that is not an
attic.
If the area above the ceil-
ing is not an attic, posi-
tion the firestop spacer
with the flange on the ceil-
ing side and the angled
portion extending up into
the hole.
If the area above the
ceiling is an attic, position
the firestop spacer with
the flange on the top of
the framed hole and the
angled portion extending
down into the hole.

FP711

Fig. 16 Install pipe, listening for the snap-lock to fasten.

UP

Lance

Hem

Pipe Rim

Pipe

Rim

WF711

STR/CVR

5/28/98

Pipe Section

Fig. 17 Attach straps to a structural framing member.

FP270/271

FP270/271

CR Series

2/19/99 djt

Elbow Strap

Support Structure

Elbow Strap

(must be tight)

Ceiling

Hole Fram-

ing

Angle Firestop

Chimney Support

Strap

(must be tight)

Angled Strap

FP593

SR/C

11/20/97

Attic Installation

Ceiling Installation

Fig. 18 Installing firestop spacer.

FP593

Nails (4)

Firestop

Spacer

Joist

Joist

Firestop

Spacer

Nails (4)

Advertising