METRObility Optical Systems R111-1T User Manual

Page 13

Advertising
background image

Radiance 10Mbps Single Interface Line Cards 13

Multimode F/O Interface
(R111-13, R111-15, R111-18)
Connector __________________________________________ SC, ST or SMA
Wavelength _________________________________________________ 820nm
RX Input Sensitivity ______________________________ -32.5 dBm minimum
Output Power ______________________ -21.8 dBm to -16.8 dBm (50/125

µ

m)

_______________________ -19 dBm to -14 dBm (62.5/125

µ

m)

Supported Link Length ___________________________ up to 2km full duplex
Cable Type ________________________________ 50/125 or 62.5/125

µ

m F/O

Multimode Fiber Optic Interface—Long Haul Distance Support
(R111-1T)
Connector _____________________________________________________ ST
Wavelength ________________________________________________ 1300nm
Output Power _______________________ -23.5 dBm to -16 dBm (50/125

µ

m)

_______________________ -20 dBm to -14 dBm (62.5/125

µ

m)

Supported Link Length ____________________________ up to 5km full duplex
Cable Type __________________________ 50/125, 62.5/125, 100/140

µ

m F/O

Advertising
This manual is related to the following products: