MaxTech FHX-1200 User Manual

Page 6

Advertising
background image

4

Section 4 - Troubleshooting

Symptom:

Partition indicator lights up.

Causes:

Hub has partitioned the 100BASE-TX (RJ-45) port due to

excessive collisions.

Solution:

If port partitioning has occurred, the hub will automatically

enable the port when the faulty condition disappears.

Symptom:

Link/Traffic indicator remains unlit.

Causes:

The workstation’s network adapter, cable or the hub port is

defective.

Solution:

The most common cause is a defective network adapter or

cable connection. Check the corresponding cable connections,
or the workstation’s network adapter for possible defects. Verify
that the correct cable type (straight-through catagory 5) is being
used (see Section 6). Replace the defective cable or adapter.

Symptom:

Port 12 and Daisy-Chain port do not work simultaneously.

Causes:

Both ports are physically the same port.

Solution:

Use either Port 12 or the Daisy-chain port.

Section 5 - Specifications

Network Standard:

IEEE 802.3u Ethernet 100Base-TX Class I and Class II
Repeater

Transfer rate:

100 Mbps

Topology:

Tree/Star

Access Method:

CSMA/CD, 100 Mbps

Media:

Catagory 5, 2 pair, UTP or STP

Max. cable length:

328 ft. (100 meters)

Ports:

12 RJ-45 jacks

Crossover connector:

1 RJ-45 (port 12)

Stackable connector:

SCSI II Cable connection

100Base-FX connector: SC connector (62.5/125)
Auto-partition:

Yes

Expandability:

72 ports (Class I)

Dimensions:

17.25” x 10.1” x 1.78”

Certification:

FCC Part 15 Class A

Temperature:

0° C to 55° C (operating)

Humidity:

5% to 95% (operating, non-condensing)

Power:

100-240VAC, 55 W max., 50/60 Hz

Section 6 - 100 Base-TX Cable Requirements

100Base-TX networks use unshielded or shielded twisted-pair cable and 8-pin RJ-
45 modular connectors. Use 22-26 AWG, 2- or 4-pair, 100 ohm/ft, solid conductor
Category 5 cable. Maximum cable length from hub to workstation is 328' (100 m).

Advertising