Specifications, Pa400 front panel functions – Marshall Amplification PA400 User Manual

Page 3

Advertising
background image

PA400 FRONT PANEL

PA400 REAR PANEL

PA400 Front Panel

Functions.

Channels 1-6

1. Low impedance XLR input - For the

connection of low impedance

microphones.

2. High impedance Jack input - For the

connection of high impedance

microphones. Also suitable for acoustic
instruments with transducer type
pick-ups.

3-5. Bass, Middle and Treble EQ controls-

A wide range of tonal adjustment can be

selected using combinations of these
controls.

6. Monitor level - Provides the volume level

adjustment from the channel to the
monitor section.

7. Effects Level - Provides level adjustment

of the signal from the channel to effects
units linked through the master effects

loop.

8. Reverb Level - Allows the level of the

built in reverb to be adjusted on the

channel.

9. Volume control - This allows the

individual volume level of the channel to
be adjusted.

Channel 7 (tape channel).

10. Tape inputs - Phono (RCA) sockets to

accept the signal from tape or CD
players.

11. Tape outputs - Phono (RCA) sockets to

provide connection out to cassette or
other recording equipment.

12. Recording level control - Provides level

control of the output to external recording
equipment.

13- 14. Bass and Treble EQ controls - A

wide range of tonal adjustment can be
selected using combinations of these

controls.

15. Monitor control - Controls the level of

the tape signal to the monitor output.

16. Volume control - Provides level control

of the tape channel output.

Master Section.

17. 9 Band Graphic Equalizer - Provides

master EQ control across the audio
spectrum. This feature is particularly

useful for "shaping" the sound to achieve
peak performance in rooms of different
size and texture. Adjustment of -12 to

+12 dB is provided at 63Hz, 125Hz, 250
Hz, 500 Hz, 1 K Hz, 2 K Hz, 4 K Hz, 8 K
Hz and 16 K Hz. The slider tips are

loaded with an LED to provide the
display of graphic "shapes", even on
darkened stages.

18. Master Volume control - Controls the

overall volume level of the amplifier.

19. Master Reverb control - Provides the

overall level control of the reverb.

20. Effects Return control - Controls the

level of the signal returning to the
PA-400 from external effects processors

which would be linked through effects
loop sockets (26 & 27).

21. Effects Send control - Controls the level

of the signal from the PA-400 to the input
of external effects processors.

22. Monitor output control - Controls the

level of the output from monitor socket
(25) to drive a separate monitor power amp.

23. Effects to Monitor control - Provides

level adjustment of the effects return into

the monitor mix.

24. Reverb to Monitor control - Provides

level adjustment of the reverb into the

monitor mix.

25. Monitor output - Jack socket for

connection to power amplifier driving the
monitor system.

26. Effects Send - Jack socket for connection

to the input of external effects processors.

27. Effects Return - Jack socket which

accepts the signal from the output of
external effects processors.

28. Footswitch socket - For connection of a

two way (FS02) switch for reverb on/off
and effects loop in/out. If a single

footswitch is used, the reverb only will be
switched.

29. Pre-amp output - Provides a signal

directly out from the pre-amp (also mutes
the power amp) allows external
processing of signal which can then be

returned to Power Amp in socket (30).

30. Power Amp input - Provides a direct

input to the power amp stage of the
PA-400. Also acts as the effects return for
series connected processors linked via

socket (29).

31. Slave output - Sends out an overall

signal from the mixer section, suitable for

driving extra power amps, if the system
needs to be extended.

Rear Panel Features.

32. Mains switch - Mains on/off switch
33. Mains Input- Socket to accept the mains

power lead supplied. (note: please ensure
that correct wiring practices have been
observed before use).

34-35. Loudspeaker outputs - Jack sockets

for the connection of loudspeaker

systems. The power output is 400 Watts
into 2 Ohms. Under no circumstances
should a total loudspeaker load of less

than 2 Ohms be connected.

SPECIFICATIONS

Channels 1-6

Low impedance

3 pin XLR balanced input.

Sensitivity

-50dBm.

Input impedance

10K

Ω.

High impedance

2 pole jack unbalanced

input.

Sensitivity

-30dBm.

Input impedance

1 M

Ω.

Bass control

+/- 12dB @ 100 Hz.

Middle control

+/- 12dB @ 600 Hz.

Treble control

+/- 12dB @ 10KHz.

Channel 7 (tape channel).

Input impedance

33K

Ω.

Input sensitivity

-20dBm.

Bass control

+/- 12dB @ 100Hz.

Treble control

+/- 12dB @ 10 KHz.

Output level

0 dBm.

Output impedance

500

.

Master section

Graphic equalizer

9 band giving +/- 12dB @

centre frequencies of

63Hz, 125Hz, 250Hz.

500Hz, 1KHz, 2KHz,

4KHz, 8KHz and16KHz.

Effects output level

0dBm nominal.

Effects output impedance

500

.

Effects input sensitivity impedance -10dBm.
Effects input impedance

10K

Ω.

Monitor output level

0dBm nominal.

Monitor output impedance

500

.

Pre-amp/slave output level

0dBm nominal.

Pre-amp/slave output

500

.

Power Amplifier

MOSFET power output stage

400 Watts into 2

Ω.

300 Watts into 4

Ω.

200 Watts into 8

Ω.

Output offset voltage

+/- 10mV.

Frequency response

+/- 0.5dB 10Hz -20KHz.

Hum and noise

Greater than -100dB.

Load impedance

2

or greater.

Output protection

Open circuit, short circuit,

load mismatch and over

temperature protection.

Input sensitivity

0dBm for 400W into 2

.

Input impedance

47K

.

Slew rate

50V /µS.

The PA-5400 has a built in cooling fan to ensure reliable operation

under the most arduous conditions. The fan will switch on when

the internal temperature exceeds 60°C and will automatically turn

off again when the temperature drops below 55°C.

8

9

1

2

3

4

5

6

7

16

15

17

18

19

20

21

22

23

24

14

13

12

11

10

25

26

27

28

29

30

31

32

33

34

Advertising