CHAPTER 7

This rigging capability allows all of the 600-HPs to be posi-
tioned at 0 degrees in relation to each other and to the MG-
MICA grid, while introducing the desired angle to the MICA
array using the GuideALinks on the lowest 600-HP enclo-
sure — without needing to adjust the angle of the remaining
600-HPs or the MG-MICA grid.

Table 7.3. 600-HP Link Positions to MICA (flown)

Rear

Front

Angle for MICA below

-3

+3

6° downtilt

0

+3

3° downtilt

0

0

3

0

3° uptilt

6

0

6° uptilt

9

0

9° uptilt

12

0

12° uptilt

15

0

15° uptilt

-3

+0

+3

0

+0

+0

+3

0

+0

-3

0

3

6

9

12

15

Figure 7.5. 600-HP to MICA flown configuration maximum angles

Ground-stacked

When MICAs are ground-stacked above the 600-HP, the
GuideALinks in MICA allow the same combinations as when
a MICA is linked with another MICA but it will create uptilt
instead of downtilt. The use of the +7 position on the front
GuideALink is not recommended.

Table 7.4. MICA Link Positions to 600-HP (ground-stacked)

Rear

Front

Angle for MICA

0

0

0.5

0

0.5° uptilt

1

0

1° uptilt

1.5

0

1.5° uptilt

2

0

2° uptilt

2.5

0

2.5° uptilt

3

0

3° uptilt

4

0

4° uptilt

5

0

5° uptilt

6

0

6° uptilt

Figure 7.6. 600-HP and MICA in a ground-stacked configuration

NOTE:

The optional MDTL-MICA downtilt

link can be used between the top 600-HP

and the first MICA in the ground-stacked array to
add a fixed amount of downtilt to the MICA section.
For more information, please see the MG-MICA
Assembly Guide (part number 05.147.034.01).

Advertising