Audio input, Amplification and protection circuitry, Power connector wiring conventions – Meyer Sound 650-P User Manual

Page 5: Trupower™ limiting system

Advertising
background image

5

Power Connector Wiring Conventions

Use the following AC cable wiring diagram to create
international or special-purpose power connectors:

brown = hot

blue =
neutral

yellow/green =
earth ground
(chassis)

AC cable color code

If the colors referred to in the diagram don't correspond
to the terminals in your plug, use the following guide-
lines:

• Connect the blue wire to the terminal marked

with an N or colored black.

• Connect the brown wire to the terminal marked

with an L or colored red.

• Connect the green and yellow wire to the terminal

marked with an E (or

) or colored green (or

green and yellow).

Audio Input

The 650-P presents a 10 kOhmbalanced input imped-
ance to a three-pin XLR connector wired with the fol-
lowing convention:

Pin 1

— 220 kOhm to chassis and earth ground (ESD

clamped)

Pin 2

— Signal

Pin 3

— Signal

Case

— Earth (AC) ground and chassis

Shorting an input connector pin to the case can form

a ground loop and cause hum.

Pins 2 and 3 carry the input as a differential signal; their
polarity can be reversed with the input polarity switch
on the user panel. If the switch is in the up position,
pin 2 is hot relative to pin 3, resulting in a positive
pressure wave when a positive signal is applied to pin 2.
Use standard audio cables with XLR connectors for
balanced signal sources.

TROUBLESHOOTING NOTE: If abnormal noise (hum,

hiss, popping) is produced from the loudspeaker, dis-

connect the audio source from the speaker. If the noise

stops, then the problem is not within the loudspeaker;

check the audio input and AC power.

A single source can drive multiple 650-Ps with a paralleled
input loop, creating an unbuffered hardwired loop
connection. Make certain that the source equipment
can drive the total load impedance presented by the
paralleled input circuit. For example, since the input
impedance of a single 650-P is 10 kOhms, cascading 20
650-Ps produces a balanced input impedance of 500
Ohms. If a 150 Ohm source is used, the 500 Ohm load
results in a 2.28 dB loss.

Amplification and Protection

Circuitry

Each driver in the 650-P is powered by one channel
of the Meyer MP-2, a 1240 W amplifier (620 W/ch)
utilizing complementary power MOSFET output stages
(class AB/H). The following sections discuss the MP-2’s
limiting circuitry and the two-fan cooling system.

TruPower™ Limiting System

Conventional limiters assume that the resistance of a
speaker remains constant and set the limiting threshold
by measuring voltage only. This method is inaccurate
because the speaker’s resistance changes in response to
the frequency content of the source material and ther-
mal variations in the speaker’s voice coil and magnet.
Conventional limiters begin limiting prematurely, which
under-utilizes system headroom and deprives the speaker
of its full dynamic range.

The TruPower limiting (TPL) system accounts for varying
speaker impedance by measuring current, in addition
to voltage, to compute the power dissipation and voice
coil temperature. TPL improves performance before and
during limiting by allowing the speaker to produce its
maximum SPL across its entire frequency range. TPL
also extends the lifetime of the drivers by controlling
the temperature of the voice coil.

Differential Inputs