Micro Technic Micronix PV-1648 User Manual

Page 2

Advertising
background image

Users Manual & Installation Guide

PV-

SERIES

:

16

D

IGITAL INPUTS

,

48

D

IGITAL OUTPUTS

Page 2 of 8

D

ESCRIPTION

Micronix PV-1648 lets you handle combined I/O from one single PC/104 board. The PV-1648

module plugs into any standard PC/- 104 bus interface and provides you with 16 digital opto-isolated

inputs and 48 NPN non-isolated open collector digital outputs (optional pull-up to +5V). Non-Stack-

through or stack-through (S-versions) connectors are available. Supplied with drivers for Windows

95/98 and NT.

F

EATURES AND SPECIFICATIONS

Inputs

Number of channels: 16 opto-isolated inputs, groups of two

Isolation:

Up to 1000 Vrms

Mix voltage range:

±30V

Current Limit Resistor: 10K

, 0.25W

Logic “1”

Uin < -10V, Uin > +10V

Logic “0”

-5V < Uin < +5V

Input delay:

ON: < 25 us

OFF: <100 us

Interrupts:

Int. 5,9,10,11,15 selectable on channel 0

Connector:

26-pin ribbon cable connector

Power requirement: +5V DC, 50mA

Outputs

Number of channels: 48 non-isolated o.c. (optional pull-up), one common GND, 4 groups of 12 bits

Voltage, load:

50V DC

Max current, load

400mA / BYTE

Max load per channel: 100mA

Saturation:

Max. 1.6V

Connector:

4 x 16-pin ribbon cable connector

Physical / Environment

Dimension:

95x90x18mm

Temperature range: Operating: 0°C to 60°C at 1.5A

Storage:

-40°C to +85°C

Humidity:

0 to 90% RH, non-condensing

PC/104 Stack-through connectors (S-versions)

Optional cable for inputs: 26-pin header to DSUB-25F, 30cm

Optional cables for outputs: 16-pin header to DSUB-15F, 30 cm

Advertising