27

IMPORTANT: Do not inflate or deflate one air chamber at a time.

When inflating or deflating, maintain a balanced air pressure

between air chambers to prevent stress or potential damage to the

inside diaphragms that separate the air chambers.

b

a

c

14778

d

a -

Valve stem

b -

Closed position

c -

Open position

d -

Valve cap

NOTE: Air pressure can be measured using the air gauge provided

with the air pump or using an accessory air pressure gauge.

1. Inflate the three side air chambers first. Inflate air chambers

as follows:

NOTE: Install the removable seat before the boat is fully inflated.

Hook the flanges that are located on the bottom of the seat into

the nylon straps on the side air chambers.

a. Fit the floorboards into the boat. Refer to Floorboard

Assembly

.

b. Unscrew the valve caps by turning a quarter of a turn

counterclockwise.

c. Make sure the valve stems are in the closed position. Push

in on the valve stem and rotate to the closed position.

d. Attach the air hose adapter to the air valve.
e. Starting at one of the air valves, inflate each air chamber

in turn, inflating only a quarter of the way full. Repeat this

procedure to evenly fill the air chambers until the air

chambers are filled to the recommended air pressure of

0.25 bar (3.6 psi).