I. Timer Record Setting (if being used):

1. From the Main Menu, select TIMER

PROGRAM SETTING. Select Pattern
P1
(P1-3 support different schedules,
selected Pattern will be used by DVR as
default). Select SET and enter time to
record. For DW enter day of week to
record where DAY is for every day, SPL
is days of week set by user at bottom of
the screen and HOL is for Holiday which is entered in Holiday Setting Menu of the Timer Program Setting menu
screen.

2. Use the Jog/Shuttle to enter Time (military) to start and stop recording. Select Mode A-D to REC. Camera

patterns A-D are setup in Timer Program Setting Main menu. Each Record Mode has ALARM and RECORD
SETTING (like in step E) plus other settings. For additional information on other supported functions like SKIP,
OVER and more, see the DVR User Manual.

3. The last setting is for MD (Motion Detection), if motion recording is being used in this set time set to ON, if not, set

to OFF.


J. Initial Setup/Information:

1. From the Main Menu Jog and Select INITIAL SETUP/INFORMATION
2. Select HDD SETTINGS, and set the HDD Repeat REC Main to ON if repeat

recording is needed (Repeat Record will write over existing data).

3. HDD REP REC SUB is used for ALARM RECORD only and set as above, if

set to OFF, when the SUB partition is full no more Alarms will be recorded.
When set to ON, Alarms are replaced FIFO.


K. Network Connection (if used, get IP, SUBNET & GATEWAY ADDRESS from network department):

1. From the Main Menu Jog and Select INITIAL SETUP/INFORMATION
2. From the SUB MENU (1) Jog and Select COMMUNICATION PORT SETTING
3. Jog and Select ETHERNET. Again with the Shuttle Select and with the Jog enter the IP ADDRESS.
4. With the Jog/Shuttle enter SUB NET MASK & GATEWAY ADDRESS, use the Shuttle to accept.
5. Use the Jog and Shuttle to go to ALARM NOTIFICATION SETTING and enter the IP ADDRESS to

be notified when a WARNING, ALARM SENSE, REC MODE (when set to ON).

Once all information is entered (fields not blinking) press SETUP Button to accept all entries. The unit will reset updating