TDXM Module Dimensions

Front

5.50 in.

(140 mm)

0.156 in. (4 mm)
dia. 4 places

5.50 in. (140 mm)

Panel

Mounting

Hole

Keps Nut

Lock

washer

Screw

3-3/8 in. (86 mm)
minimum mounting
clearence.

NOTE: Ground stud connection
is only for single wire to
equipment ground. Do NOT
use for more than one wire.

49/64 in.

(19 mm)

5-1/4 in.

(133 mm)

TDXM

6.0 in.

(152.3 mm)

3.0 in.

(76 mm)

3.0 in.

(76 mm)

6.0 in. (152.3 mm)

Mounting Hole

SP

HISTORY

CHANNEL

SP1 - 3

TC TYPE/UNITS (SETUP 1)
0 = IGNORE
1 = TYPE J TC. DEG F
2 = TYPE K TC. DEG F
3 = TYPE J TC. DEG C
4 = TYPE K TC. DEG C

RTU/BAUD (SETUP 7)
BAUD SETUP
0 = 9600 (N, 8, 1)
1 = 19.2K (N, 8, 1)
2 = 38.4K (N, 8, 1)
3 = 9600 (N, 8, 2)
4 = 19.2K (N, 8, 2)
5 = 38.4K (N, 8, 2)

SETUP NUMBERS
0 = EXIT
1 = TC TYPE UNIT
2 = OFFSET
3 = SETPOINTS
4 = GRP/DEV A (SP1 OUT)
GRP/DEV B (SP2 OUT)
5 = CH SCAN DELAY
6 = CJ DISPLAY
7 = RTU/BAUD
8 = UNIT ID

CJ DISPLAY (SETUP 6)
0 = DISABLE
1 = ENABLE, DEG F
2 = ENABLE, DEG C

TDXM-DC

POWER INPUT: 10-32 VDC

OUTPUT TYPE AND RATING:

SP1: FET, OPEN DRAIN,

350 VDC, 0.5A MAX.

SP2: FET, OPEN DRAIN,

350 VDC, 0.5A MAX.

SP3: SSR, FORM C,

350 VDC/240 VAC, 0.12A MAX.

NON-INCENDIVE FIELD

WIRING CONNECTIONS

FOR USE IN CLASS I

DIV. 2, GROUPS C & D

LOCATIONS WHEN INSTALLED PER

MURPHY DRAWING 10-08-0006

THERMOCOUPLE INPUTS

(WHITE / YELLOW)

SCROLL

ENTER

®

MODEL

NO:

TDXM-DC

V

OLT

AG

E:

10V

DC

M

I

N

,32V

DC

M

A

X

,500mW,

NE

GG

ND

X

,

CS

A

CE

RT

I

F

I

ED

FO

R

CL

I,

D

IV

2,G

RPS

C

&

D

D

W

HEN

I

NS

T

A

LLED

PE

R

M

URP

HY

DR

AWI

N

G10

-

0

8-

000

6

U

SE

R

IA

L

NO:

X9

-xxxx

-X-

X

F

W

M

URP

HYH

SE

R

IA

L

NO:

X9

-xxxx

-X-

X

F

W

M

URP

HYH

6-1/2 in. (165 mm)

6-1/2 in.

(165 mm)

(SETUP)

(SETUP)

C US

Head/Module

TDXM-DC: 24-channel model, 10-32 VDC powered.

TDXM-DC W/SP3 Latch: Same as TDXM-DC but

with SP3 latch feature.

Configuration Software

MConfig: TDXM configuration software available.

Replacement Parts

Plug, kit, TDXM: Terminal Plug replacement kit-P/N

10-00-7848.

Shipping Weights and Dimensions
Shipping Weight (all Models):
3 lb. (1.36 kg) approximately.
Shipping Dimensions (all Models): 5-1/2 x 9 x 9-1/2 in.

(140 x 229 x 241 mm) approximately.

Warranty

A limited warranty on materials and workmanship is given with this FW Murphy
product. A copy of the warranty may be viewed or printed by going to
www.fwmurphy.com/support/warranty.htm

Side

Back

How to Order Your TDXM

Specify the following part number:

For Outdoor Use, the TDXM should be mounted in a weatherproof enclosure

TDXM-00064B page 2 of 2

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
specifications and designs at any time. MURPHY, the Murphy logo are registered and/or common law trademarks
of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright protected by
Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc.

www.fwmurphy.com

918.317.4100 Email: [email protected]

Advertising