All-In-One Wireless Security System (MG-6130/MG-6160)

What’s New V2.0

32 Zones:

• Now supports 32 zones instead of 16.

• New zone display:

New 13.8Vdc, 200mA Auxiliary Output:

• Requires a DC (12Vdc to 18Vdc, 1A) or AC (12Vac to 16Vac,

20VA) power source. If you do not plan to use the auxilary output,
an output value of smaller than 12Vdc will be enough.

Note: When a power failure occurs, the auxiliary output will drop to 7Vdc (backup battery)

Supports up to 4 Wireless Keypads (MG32WK)

• Can be programmed with the Installer Quick Menu by entering

Menu 4 (System Setup) followed by Menu 8 (Keypad Profile)

• Assign keypads in sections [243] to [246].

• Set keypad supervision in section [295], options [1] to [4].

• Set Live Display Mode in section [095], option [6].

• Related events in PGM Event Table: Event Group # 47 to 52.

• For more details, refer to the console’s Programming Guide.

Supports up to 2 Wireless Repeater Modules (MG-RPT1)

• Can be programmed with the Installer Quick Menu by entering

Menu 4 (System Setup) followed by Menu 9 (Repeater Profile)

• Assign repeater in sections [247] to [248].

• Set repeater supervision in section [296], options [1] and [2].

• Set repeater options in sections [300] to [311].

• Related events in PGM Event Table: Event Group # 53 to 58.

• For more details, refer to the console’s Programming Guide.

Voice Reporting:

• Five telephone numbers can now be contacted by the MG-6130/MG-6160 instead of two. These telephone numbers

are programmed through the console’s communicator menu.

• Remote Access mode allows the user to manage the system remotely by telephone. It can now be accessed through

voice reporting. When in alarm, the system calls to play the pre-recorded message, lists all zones in alarm, and
guides the user via a menu where they can perform actions including disarming the system.

Off =

Viewing zones 1 to 16

On =

Viewing zones 1 to 16,
and a zone above 16 is open

Flashing =

Viewing zones 17 to 32

Press to toggle zone view (1-16 or 17-32)

Power Source

Auxilary Output

12Vdc

11Vdc (Appx.)

15Vdc to 18Vdc

13.8Vdc

12Vac

12Vdc (Appx.)

16Vac

13.8Vdc