FOR YOUR SAFETY

Do not store or use gasoline or other

flammable vapors and liquids in the

vicinity of this or any other appliance

NOTE: Instructions to be followed in the event
the operator smells gas, should be posted in a
prominent location. This information can be
obtained by consulting your local gas supplier.

BEFORE INSTALLATION

NOTE: Upon receipt of this unit, immediately unpack and inspect for possible concealed
shipping damage. If unit is found to be damaged, save all packing materials and contact your
delivery carrier within 5 days. Refer to “Shipping Damage Instructions” enclosed for detailed
instructions. Failure to follow these instructions will negate Merco/Savory’s or your ability to
file claims and receive compensation for shipping damage.

WARNING:

Improper installation, adjustment, alteration

service or maintenance can cause property damage, injury or
death. Read the Installation & Operation and Maintenance
instructions thoroughly before installation or servicing this
equipment.

INSTALLATION INSTRUCTIONS

Install the CG-30 toaster in the most convenient location for ease of cleaning, maintenance and general operation. Avoid
installing in locations with drafts, close proximity to grease or vapor-producing appliances or other high ambient heat
equipment. For cafeteria or waiter type operation, the toaster should be set for rear delivery, with the receiving tray facing
the traffic flow. Front Delivery: Insert delivery chute through front opening with lipped end held. Push delivery chute rear
up and back until notches fall over chute pins. Rear Delivery: Insert delivery chute through rear opening with lipped end
held. Push delivery chute rear up and back until notches fall over chute pins.

IMPORTANT

Toaster should be installed in an area free and clear of combustibles. The area should have no obstructions
to the flow of combustion and ventilation air. Provisions should be made for adequate air supply in the room
where the toaster is installed. Maintain adequate clearance for air openings into the combustion chamber.

MINIMUM CLEARANCE FROM COMBUSTIBLE AND NONCOMBUSTIBLE

CONSTRUCTION IS 6” FROM EACH SIDE AND 6” FROM REAR OF UNIT.

SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOORS.

Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding plug) for your protection
against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.

A gas pressure regulator is provided for use with both natural gas and propane gas. It is recommended that a flexible
metal connector be installed between the toaster and the gas supply line. The connector should comply with the latest
edition of the Standard for Connectors for Moveable Gas Appliance ANSI Z21.69 and that adequate means must be
provided to limit the movement of the unit without depending on the connector and any quick disconnect device or its
associated piping to limit the unit movement. The connector should be of the appropriate length and equipped with a quick
disconnect coupling containing a feasible link (Savory Part #25209). This will permit portability for ease of cleaning, adjust-
ments and service. Minimum inlet pressure for natural gas is 5” w.c. Minimum inlet pressure for propane gas is 11” w.c.
Electrical grounding of the installed toaster is required. The CG-30 toaster is factory supplied with a 6’ cord and NEMA5-
15P plug. Electrical power required to operate the conveyor motor and the burner control valves is only 40.2 watts which is
readily available at most electrical outlets. This toaster must be electrically grounded in accordance with local codes, or in
the absence of local codes, with the latest edition of the National Electrical Code ANSI/NFPA 70 or the CSA C-22.2.
NOTE: Wiring diagram is permanently attached to the inner surface of the removable right side panel.