Momentum mo8 Manual

This function sequentially routes all eight output channels to match a corresponding input device.

The start channel route is primarily used during the initial set up of the system. Channels are set

in grouping of eight i.e. 1-8, 9-16, 17-24 etc. If “- - -” shows on the display, it indicates that one

or any of the channels is out of sequence. To individually route channels use the “rou” function.

See page 17 for details on the “rou” function.

Start Channel Route

Connection and Setup

Chapter 2

An IP address will need to be set only if the Momentum

network will be controlled with a PC or external controller.

The IP address defaults to 192.168.1.1. When in the idle

menu state, pressing the F1 button will fl ash the current ad-

dress. The number shown is the LSB of the IP address

(192.168.1.[LSB]). If the network is to be controlled with

a PC, each mi8 unit will need a unique IP address. All IPs

need to be set manually on the individual unit.

It is best practice to keep the input unit’s IP address sequential with its channel. In other words,

Chn 001-008 would be Adr 001 and Chn 009-016 would be Adr 002 and so on.

ALL DEVICES in the network must be set at a sample rate of either 48k or 96k.

IP Address

Sample Rate

THE FOLLOWING FRONT PANEL SETTINGS MUST BE CONFIGURED PRIOR TO USING MOMENTUM.

The IP setting is required only if the unit will be controlled with a PC or external controller.

A detailed description of control functions can be found in chapter 3, pages 16-18.

Setting Device Before Use