8. Settings in GX Developer

Set the IP address, the TCP port number and the connection route, etc. on the
Transfer setup dialog box, when accessing FX1S, FX1N, FX2N, or FX2NC Series
PLC via Ethernet from GX Developer.

Note:

• GX Developer must be Version 8.25B or later.
• FX Configurator-EN must be installed on the personal computer.

For details on the installation method of FX Configurator-EN, refer to the FX
Configurator-EN Operation Manual.

8.1 Setting method

Select [Online]

→ [Transfer setup]

8.2 Operations

In GX Developer, operations such as upload, download, monitoring and test of a
program are performed in the same way as with serial communication.

Click “Ethernet board”

Double-click “Ethernet module”

Set the TCP Port Number (Port

No.) connection destination as

assigned to the FX

2NC

-ENET-ADP

by the sequence program.

For details on the TCP port Number

setting for the FX

2NC

-ENET-ADP,

refer to Chapter 7.

Set the IP address connection

destination as assigned to the

FX

2NC

-ENET-ADP by the sequence

program. (When using the Host

Name, set the name assigned by

the hosts file within 64 characters.)

For details on the IP address

setting for the FX

2NC

-ENET-ADP,

refer to Chapter 7.

Select FX

2NC

-ENET-ADP.

9. Setting in MX Component

Note:

• MX Component must be Version 3.08J or later.
• FX Configurator-EN must be installed on the personal computer.

For details on the installation method of FX Configurator-EN, refer to the FX
Configurator-EN Operation Manual.

Note; In case of Virtual COM Port (VCP) Driver

If using Virtual COM Port (VCP) Driver, add the Logical station number for Ethernet.

9.1 Setting method

Select [Programs] - [MELSOFT Application] - [MX Component] - [Communication
Setup Utility].

[Wizard]

Select the "Logical station number".

[Next]

First, set "Ethernet board" at [PC

side I/F]. Next, set "FX-ENET

(-ADP)" at [Connect module].

[Next]

First, set "Ethernet module" at [PLC side I/F].

Next, set "FX-ENET-ADP" at [Module type].

Set the TCP Port Number (Port No)

connection destination as assigned

to the FX

2NC

-ENET-ADP by the

sequence program.

For details on the TCP port Number

setting for the FX

2NC

-ENET-ADP,

refer to Chapter 7.

Set the IP address connection

destination as assigned to the

FX

2NC

-ENET-ADP by the sequence

program. (When using the Host

Name, set the name assigned by

the hosts file.)

For details on the IP address setting

for the FX

2NC

-ENET-ADP, refer to

Chapter 7.

[Next]

Set FX

1S

, FX

1N

, FX

2N

or

FX

2NC

at [CPU type].

[Next]

Enter a comment.

[Finish]

10. Troubleshooting

Turn ON power of PLC.

Is POWER

LED ON?

Is LINK

LED ON?

Two seconds after

FX

2NC

-ENET-ADP is

turned ON

Check the cable connection between

FX

2NC

-ENET-ADP and PLC.

Check if FX

2NC

-ENET-ADP and HUB are

connected correctly.

Check if power of HUB is ON.

Are FX

2NC

-ENET-ADP

and PLC connected

correctly?

SD LED:ON

RD LED:OFF

Connect

cable

correctly.

Check Ethernet

parameters.

For details, refer

to "7. Parameter

Settings for

FX

2NC

-ENET-

ADP".

Parameters

are read

correctly

from PLC.

Is communication

port set for computer

link or no protocol

communication?

(Value other than 0

stored in D8120.)

Clear communication

parameter check box,

and download

program.

SD LED:OFF

RD LED:ON

SD LED:OFF

RD LED:OFF

Yes

No

No

Yes

No

No

Yes

Yes

No

Yes

Yes

Yes

Turn ON power again.

Is any

numeric value

other than 0 stored in

D8120?

Set 0 to D8120.

Turn ON power again.

Check if PLC and PC

are connected

correctly.

Execute PING

command for IP

address set to PLC.*

Any response?

1) Check again IP address set to PLC.

2) Confirm that network address in PLC

matches network address in PC.

3) Confirm connection of Ethernet

between PC and PLC.

Confirm that TCP port number set in GX

Developer or MX Component matches TCP

port number set in PLC.

[Reference]

The PING command confirms confirmation whether the communication

between Ethernet devices using the IP address of TCP/IP is possible.

Execute the PING command from the personal computer connected to

Ethernet, and check whether the FX

2NC

-ENET-ADP sends a response.

Refer to the PING command described below.

Executing the PING command

Open the MS-DOS prompt (command prompt in the Windows2000/XP).

In the example parameter settings in Section 7.3, the IP address is set

to "192.168.0.110".

PING 192.168.0.110

No

Yes

No

Yes

Clear the check box.

*