Meco Electric Water Cooler User Manual

Page 3

Advertising
background image

- 3 -

ALL RIGHTS RESERVED © MECO 2003

Installation Instructions

1) To facilitate proper air circulation, the cooler should not be installed in any enclosed

or confined space.

2) Prior to installation, remove back cover of cooler and visually inspect for transit

damage. Temporarily connect cooler to electric supply and switch on the thermostat.
Check that fan is operating and not jammed.

3) For installation, connect the water inlet and wastewater drain connections. Do not

use excessive force on the brass inlet and drain connectors of the cooler, as this
tends to damage it.

4) Connect 3-pin 15-ampere plug to the cooler's main power cable with the green or

yellow wire connected to the earthing terminal of the plug.

5) Always use a proper circuit breaker to avoid compressor burnout.

Automatic voltage stabilizer should be used in low voltage areas.

Specifications

Cabinet

Made of heavy gauge vinyl-coated and stainless steel sheets, in various pleasing
colours. Drain pot made of hard plastic, or stainless steel. Back panel easily removable
for cleaning and servicing. Top cover of plastic (except model 100P). Base of plastic /
stainless.

Refrigeration System

Fitted with world renowned, high starting torque, high temperature compressors.
Condenser and fan are slightly oversized to ensure efficient working in high
temperatures. Copper cooling coil metal bonded to outside of water tank. Whole system
hermetically sealed with R-22 (or R-12) as refrigerant.

Water System

All copper / brass water system. Water tank made of heavy gauge copper sheet tinned
from inside. Tank safety tested at 10 kg/cm

2

(142 p.s.i.) with recommended maximum

working pressure of 5 kg/cm

2

(71 p.s.i.). Fitted with high quality chrome plated brass

taps.

Insulation

Moisture proof and highly effective polyurethane or polystyrene insulation.

Advertising