Troubleshooting – Moyer Diebel DF1-M6 User Manual

Page 16

Advertising
background image

14

TROUBLESHOOTING

CONDITION

CAUSE

SOLUTION

Conveyor does not turn

No power.............................................Check fuse panel

Turn power switch on

Drive motor burnt out .........................Replace
Obstruction in wash or rinse ..............Remove obstruction
Micro-switch on switch support..........Adjust or replace
bracket faulty or not making
contact
Conveyor not in position.....................Position properly

Excessive overspray

Splash curtain not in position ............Install or adjust

from hood section

Washer running without any ...............Keep conveyor loaded with glasses
glasses on conveyor
Spray tubes fallen off hub ...................Ensure spray tube is pushed firmly on to hub

connection

Spray tubes plugged............................Clear and clean with reamer, scraper, and

brush

Lack of pressure at wash

No water in detergent tank..................Ensure water supply is on

spray tubes

Ensure detergent tank stand pipe is in postion
Ensure the tank fill switch is in “ON-FILL”
position and that tank fills with water
Ensure the float switch is activated by the float
cam
Ensure the tank fill solenoid valve is
operational

Obstruction in wash arm .....................Clear obstruction
Pump not operating .............................Check power supply to machine

Check pump capacitor
Replace pump if required

Pump operating but no pressure..........Check condition of impeller and stub shaft

Replace if needed

Lack of pressure in rinse

Rinse spray tubes dirty........................Clean thoroughly with reamer, scraper, and

spray tubes

brush provided

Shut-off valve on supply .....................Open valve
line closed
Low water pressure .............................Minimum 25PSI flow pressure required
Rinse solenoid valve will ...................Check coil
not operate

Check and install rebuild kit
Replace if necessary

Rinse solenoid valve strainer .............Remove screen and clean
plugged

Water continues to flow to

Solenoid valve not seating ..................Clean seat

detergent tank or spray tubes

Install diaphragm kit

with machine off

Replace valve

TROUBLESHOOTING