Cleaning

9

e. Dry the racks thoroughly with a dry cloth and polish

with a soft dry cloth.

f. To refit the racks, engage the front and rear upper

rack keyholes onto the upper hanger studs.

g. Raise the rack up again slightly until the lower rack

keyholes engage onto the lower studs, ensuring that
the upper studs remain engaged.

h. Push down on the rack to ensure that it is fully

engaged onto the upper and lower hanger studs.


NOTE: Ensure that the rack is securely fitted and that

ALL the studs are engaged into the rack key
holes.

Water Tank

It is recommended that this procedure is carried out
once a week. Frequency of cleaning the element
may be increased or decreased depending on the
quantity of scale depositing on the element.

a. To remove the water tank, remove the RH side rack

as shown previously.

b.

Remove the water tank by lifting the tank off its

hanger studs. Clean with warm soapy water. Rinse
thoroughly and refit.

Water Tank Element

a.

When the wet element becomes limed / scaled up,

remove the water tank and clean as shown
previously.

b.

Refit the water tank and half fill with white vinegar

or acetic acid, then fill to the normal level with
water. Switch ‘On’ the unit, and turn the Humidity
Control to ‘8’. Operate for approximately 30
minutes.

c.

When cooled, remove the water tank and clean the

element with a damp cloth. Rinse out the water
tank and refit to the unit.

Door

a. Wash with warm water and a mild detergent

solution using a soft sponge in straight lines up and
down the inner and outer surfaces of the door.
Rinse with clean, warm water and dry off.

b. Dry the door thoroughly with a soft dry cloth.
c. Clean door glass with a conventional glass cleaner.

Condensation Channel

a. Below the door is a condensation channel for

collecting door condensation run-off. This is then
fed into a condensation drawer.

b. Empty the condensation drawer on a regular basis

and once a week, wipe out the condensation
channel and drawer with a damp cloth moistened
with warm water and a mild detergent solution.

c. Dry with a soft dry cloth.

Door Seal

Clean the door seal with warm water and a detergent
solution using a soft sponge when required.

Should the door seal become dirty, it can be removed
for a more thorough cleaning should this be necessary:-

a. To remove the 1 piece seal, pull seal forward until it

pulls out of the location groove around the door.

b. Note the way the seal is fitted to the door,

with the lip facing inwards.

c. Check the seal for wear and damage and replace if

damaged or worn.

d. The seal may be washed in a sink, taking care not

to cut or damage the seal.

e. Dry the seal thoroughly with a soft dry cloth before

re-fitting.

f. To refit seal, have lip facing into the centre of door.
g. Press the seal into the locating groove around the

door until the seal is properly located.

Water Tank