The H635 10Base-T ethernet hub

creates a home network between up

to five computers. “Plug and play” installation is easy when using the H628 data

hub.

The H635 is fully

IEEE802.3 10Base-T compliant
and has activity LEDs for network
status and diagnosis. The H635
has an “uplink” port to expand the
network using additional H635
units for systems with more than
five devices.

ChannelPlus Ethernet Hub

1

2

3

1) Hook from the top

2) Swing into place

3) Push button to lock

OpenHouse modules attach from the top

tm

ChannelPlus model H616

Telephone Master Hub (4 lines x 6 phones)

Telephone Master Hub (4 lines x 6 phones)

Telephones

From

Telco

From

Telco

RJ31X

Out

Expansion

Ports

Expansion

Ports

R

T

R

T

4

R

T

R

T

3

R

T

R

T

2

R

T

R

T

1

Typical Installation

Expanding the Network

Wiring the H635 Hub

LED Indicators

- Use only Category 5 unshielded twisted-pair cable.

- When connecting to an H628 or a network device directly, use

straight through RJ-45 cables.

- Each run to a network device should be less than 100 meters (328

feet).

- PWR indicates that the unit is powered and should be operating

normally. If the PWR light is not on, check to make sure the outlet

is on and the power supply is connected properly.

- LINK/ACT lights are on when a network device is detected and

operating normally. Each of the five ports has its own LINK/ACT

light.

- COL indicates that a network collision has occurred. Although

some amount of collision usually occurs, too many collisions may

indicate a problem such as a faulty cable connection.

DECLARATION OF CONFORMITY

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE

FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2)

THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY

CAUSE UNDESIRED OPERATION.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15

of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a

residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not

installed and used according to the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does

cause harmful interference to radio or television reception, which if found by turning the equipment off and on, the

user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna

-Increase the separation between the equipment and receiver.

-Connect the equipment to an outlet other than the receiver’s outlet.

-Consult a dealer or an experienced radio/TV technician for assistance.

Power supply

LED Indicators

Network Interface

model number

105-125 VAC

LINK/ACT

1

800mA maximum

5 VDC ± 5% regulated

PWR, COL

5

350-087

input power

each port

RJ-45 uplink

output voltage

each unit

RJ-45 ports

output current

Environmental

Compliance

operating temperature

IEEE 802.3

0°C to 50°C

10Base-T

Max cable length

CAT-5 (UTP)

100 meters (328 feet)

Specifications: typical @ 25 C ± 5 C

O

O

H635

ChannelPlus model H635

Ethernet Hub

BASE-T (5 RJ-45 inputs, 1 uplink)

10

Link/Act.

1

2

3

4

5

Col.

Pwr

Uplink

5

4

3

2

1

+5VDC

TM

ChannelPlus model H635

Ethernet Hub

BASE-T (5 RJ-45 inputs, 1 uplink)

10

Link/Act.

1

2

3

4

5

Col.

Pwr

Uplink

5

4

3

2

1

+5VDC

TM

ChannelPlus model H628

Data Hub (8 cables, TIA-568A) Category 5 Compliant

H628

H691

H635

Ethernet hub

H635

Ethernet hub

H635

Ethernet hub

(expansion)

Ethernet connections for 5 rooms

Leave this port unused

}

To data jacks

in remote

wall plates

ChannelPlus model H635

Ethernet Hub

BASE-T (5 RJ-45 inputs, 1 uplink)

10

Link/Act.

1

2

3

4

5

Col.

Pwr

Uplink

5

4

3

2

1

+5VDC

TM

ChannelPlus model H635

Ethernet Hub

BASE-T (5 RJ-45 inputs, 1 uplink)

10

Link/Act.

1

2

3

4

5

Col.

Pwr

Uplink

5

4

3

2

1

+5VDC

TM

Use one of the ports on the first H635 and connect to the

expansion H635 using its “uplink” port. See below for special

instructions.

Using more than one hub

- Use only Category 5 unshielded twisted-pair cable.

- When connecting two hubs, use only a straight through RJ-45

Category 5 cable.

- The cable length between two hubs cannot exceed 100 meters

(328 feet).

- Additional hubs may be used as long as the path between any

two network devices does not exceed four hubs and five cables.

- When using the uplink port on an H635, you cannot connect a

network device to port 5.

- All hubs used must be powered.

}

}

Connect to 4 network

devices or to the “uplink”

port of additional H635 hubs.

Connect to 4 network

devices or to the “uplink”

port of additional H635 hubs.