Master Lock 70000 BTU/Hr User Manual

Page 12

Advertising
background image

12

101585

Air Output, Air Intake,
and Lint Filters

1. Remove upper shell (see

page 10).

2. Remove filter end cover

screws using 5/16" nut-
driver.

3. Remove filter end cover.
4. Replace air output and lint

filters.

5. Wash or replace air intake

filter (see Preventative
Maintenance Schedule,
page 8).

6. Replace filter end cover.
7. Replace fan guard and

upper shell.

IMPORTANT:

Do not oil

filters.

Air Intake Filter

Lint Filter

Filter End
Cover

Air Output
Filter

Fan Guard

Figure 14 - Air Output, Air Intake, and Lint Filters,

70,000 BTU/Hr Model

Air Intake Filter

Filter End
Cover

Lint Filter

Air Output
Filter

Figure 15 - Air Output, Air Intake, and Lint Filters,

100,000/150,000 BTU/Hr Models

PRESSURE GAUGE PLUG

PFA/OV 006B

Figure 16 - Pressure Gauge Plug Removal

Pressure
Gauge
Plug

Pressure
Gauge

Figure 17 - Adjusting Pump Pressure

Pump

Model

Pressure

70,000 BTU/Hr

4.5 PSI

100,000 BTU/Hr

4.5 PSI

150,000 BTU/Hr

4.9 PSI

Pump Pressure
Adjustment

1. Remove pressure gauge

plug from filter end cover.

2. Install accessory pressure

gauge (part number
HA1180).

3. Start heater (see Operation,

page 7). Allow motor to
reach full speed.

4. Adjust pressure. Turn relief

valve to right to increase
pressure. Turn relief valve
to left to decrease pressure.
See specifications at right
for correct pressure for
each model.

5. Remove pressure gauge.

Replace pressure gauge
plug in filter end cover.

(70,000 BTU/Hr Model Shown)

Relief
Valve

Fan Guard

Advertising
This manual is related to the following products: