Indicators, En – 24, Normal condition abnormal condition – MITSUBISHI ELECTRIC XL1X S L 2 User Manual

Page 24: Menu enter mute, Power lamp temp condition possible solutions, Lamp indicator power indicator temp indicator, Volume source

Advertising
background image

EN – 24

Indicators

The projector has three LED Indicators which shows the working condition of the projector.
The following offers solutions to possible problems. If a problem persists, turn the projector off and consult your
dealer.

Normal condition

Abnormal condition

Steady

red

Steady

green

Steady

green

Blinking

green

Steady

green

POWER LAMP

TEMP

CONDITION

Notes

The POWER is ON. (Normal condition)

Lamp stand-by (about for 1 minute)

The power button cannot be used to switch
ON and OFF

Stand-by

Off

Off

Off

Off

Steady

green

Blinking

green/red

Blinking

green/red

Blinking

green/red

Steady

red

Steady

green

Steady

green

Blinking

red

Blinking

red

POWER LAMP

TEMP

CONDITION

POSSIBLE SOLUTIONS

Steady

red

Blinking

red

Steady

red

Close the cover correctly.

or

or

Blinking

Blinking

Abnormal.

Contact your dealer.

Off

Off

Steady

red

Blinking

green

Off

Off

Off

Off

Off

Steady

red

Steady

Steady

Unusual temperature
• The ventilation slits or air filter is clogged with

dust or debris.

• The room temperature is too high.
• The filter is dirty.

• Remove the object from the ventilation

slits.

• Relocate the projector to a cooler place.
• Clean the filter.

Replace the lamp.
Exchange with a new lamp if the same
problem recurs.

• Wait until the LAMP indicator is turned

off, then press the POWER button.

• If the above operation is not effective,

replace the lamp.

The lamp cover is not closed.

The protection circuit is working or the lamp is in an
abnormal condition.

(The indicators operate as shown on the left at the time of
power-off, too. In this case, they are’nt indicating an
abnormal condision.)

The lamp operation time exceeds the time elapsed until the
lamp shutdown notice. (See page 21.) The POWER is on.

The lamp operation time exceeds the time elapsed until the
lamp shutdown notice. (See page 21.) The POWER is off.

The lamp operation time exceeds the time elapsed until the
lamp shutdown. (See page 21.)

LAMP indicator

POWER indicator

TEMP indicator

TEMP

LAMP

VOLUME

SOURCE

COMPUTER

VIDEO

AUTO

POSITION

MENU

ENTER

MUTE

Advertising