099565

How To

See Storage, page 9.

Lift out of fuel tank and rinse

with clean kerosene.

See Fuel Filters, page 17.

See Fuel Lines, Page 16.

See Fuel Filters, page 17.

See Spark Plug, page 15.

See Fan Blades, page 14.

Remove dirt and trash with

clean, soft cloth.

PREVENTATIVE

MAINTENANCE

SCHEDULE

Item

Fuel tank

Filler neck screen

Fuel filter assembly

(Fuel tank)

Fuel filter lines

Fuel filter (Pump)

Spark plug

Fan blades

Air passages around

burner head

Motor

How Often

Flush every 150-200 hours

of operation or as needed.

Check for trash when

filling fuel tank. Clean
when dirty.

Clean twice a heating

season or replace as
needed.

Check and tighten loose

connections occasionally.

Clean fuel filter element

every 250 hours.

Clean and regap every 300

hours of operation or
replace as needed.

Clean each season or as

needed.

Check each season for dirt

and trash.

Not required, permanently

lubricated.

WARNING ICON

G 001

WARNING

Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur.