Volume management for x-raid – ioSafe R4 User Manual

Page 41

Advertising
background image

P/N: 900-10004-00 REV 02 USER GUIDE, IOSAFE R4

41

We can also remove a disk from the volume by clicking on the Remove button. The volume will
still be available but in a non-redundant state. An additional disk failure would render this volume
unusable.

Warning

The Remove operation is a maintenance feature and is not recommended in
a live environment. Its function is equivalent to hot-removing the disk or
simulating a disk failure.

The Locate option is a way to verify that a disk is correctly situated in the expected disk slot.
Clicking on Locate will blink the LED of the disk for 15 seconds.

Volume Management for X-RAID

The X-RAID technology offers a simplified approach to volume management. X-RAID works on
the premise that what most people want to do with their data volume over time is either adding
redundancy or expanding it without the headaches usually associated with doing that. By using
simple rules, X-RAID is able to hide all the complexities yet provide volume management features
only previously available in enterprise-level storage solutions.

X - R A I D R E D U N D A N C Y O V E R H E A D

To maintain redundancy from disk failure, X-RAID requires a one-disk overhead. In a two-disk X-
RAID volume, the usable capacity is one disk. In a three-disk X-RAID volume, the usable capacity
is two disks. In a four-disk X-RAID volume, the usable capacity is three disks.