Mage alignment, Image alignment – IDEAL INDUSTRIES Dual View Thermal Imaging Camera HeatSeeker 160 User Manual

Page 8

Advertising
background image

#61-846

ND-7521-1

Page 8 of 25

4.2. Image alignment

As the visible and thermal cameras are not co-axial the visible and thermal image may need to
be aligned. This is usually required when moving to view objects at different distances.

4.2.1.

Press Function Key 1

to toggle to the alignment icon

.

4.2.2.

Use the up/down and left/right navigation buttons

to align the thermal

and visible images.

Note The visible image is moved during alignment.

Examples of alignment.

Fully Aligned

Align left

Align right

Align up

Align down


Four pre-programmed alignment distances are included. These are at 1.5ft, 3ft, 6ft and

12ft ranges. With the alignment option selected by function key 1, pressing the center
navigation button once aligns at 6ft. Pressing the center navigation button repeatedly
cycles through to 12ft, 1.5ft and 3ft.

Note: These values appear in Metres if °C is selected.

Advertising