Troubleshooting – Iomega HIGH FPD1000-HP User Manual

Page 5

Advertising
background image

3

Symptom

Probable Cause

Corrective Action

FLUID WILL NOT

1. Foreign matter blocking

Dismantle meter, clean rotors. Strainer must

FLOW THROUGH

rotors

be fitted in-line.

THE METER

2. Line strainer blocked

Clean strainer.

3. Damaged rotors

Replace rotors. Strainer must be fitted in-line.

4. Meter connections over-

Re-adjust connections.

tightened

REDUCED FLOW

1. Line strainer partially

Clean strainer.

THROUGH THE

blocked

METER

2. Fluid is too viscous

Maximum viscosity 1000 centipoise.

METER READING

1. Fluid flowrate is too low

See specifications for minimum and

INACCURATE

or too high

maximum flowrates.

2. Air in fluid.

Bleed air from system.

3. Excess wear caused by

Check meter for damage. Install correctly.

incorrect installation

METER NOT

1. Faulty Hall Effect sensor

Replace meter cap for Reed Switch models,

GIVING A PULSE

or Reed Switch

replace PCB for Hall Effect models.

SIGNAL

2. Faulty magnet

Replace rotors.

TROUBLESHOOTING