7. Reinstall the UV sheild

according to the following

illustration.

8. First, insert the bottom

of the filter into the air

cleaner and then insert

the top of the filter.

9. Insert the top of the inlet

grill first and then snap in

the lower part of the grill.

REPlaCInG ThE uV laMP

uV laMP SaFETY WaRnInG:
To prevent exposure to ultraviolet light, disconnect power to the unit

before servicing any part of the Therapure

®

300D air purifier.

Before replacing the UV lamp of your Therapure

®

300D

air purifier, turn off and unplug the unit from the electrical

outlet and read all safety instructions and important

warnings in this owner’s manual.

Replace your UV lamp every year. Call 800.875.8577

or visit www.therapureair.com.

1. First turn off and unplug your

Therapure

®

300D air purifier.

With the front of the unit facing

up, pull up the lower end of the

inlet grill and push it toward the

display panel at the top of the

unit as shown below.

2. Remove the permanent filter by

lifting and pulling the string.

3. Remove the screws on

the UV shield by using a

screwdriver. Allow the UV lamp

to cool at least 15 minutes.

4. Remove UV sheild.
5. Gently rotate the lamp a

quarter turn in either direction

until it unlocks from the socket.

The lamp removes and installs

in the same way as a

flourescent light lamp.

Pull out the lamp.

6. Unpack the new UV lamp gently

by handling the ends only.

Starting at one end of the

lamp, then the other, gently

insert the metal pins on the

lamp into the white slotted

socket, one pin at a time. Once

the ends of the lamp are

completely inserted into the

socket, rotate the lamp a

quarter turn until it locks

into place.

cleaning & maintenance

Caution:

Do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness

of the lamp.

Never operate the unit without a filter or with a damaged filter. The UV light from the UV

lamp will result in severe damage to eyes and could cause blindness.

uV lamp notice Warning
UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision.

Never look directly at the UV lamp while it is illuminated-doing so could cause loss of vision!

To oRDER a REPlaCEMEnT uV laMP

If your UV Lamp(s) is broken or needs replacing, simply contact us at 1.800.875.8577

or visit us online at www.therapureair.com.
Therapure

®

replacement lamp part number is TPG63000.