FAULT DIAGNOSIS

WHY DOES IT HAPPEN?

PILOT LAMP DOES NOT GLOW.

q

Check if the machine is ON.

q

Check for loose connections in plug/socket.

q

Check for blown fuse

WATER DOES NOT ENTER MACHINE/DETERGENT NOT

BEING FLUSHED INTO DRUM.

q

Check water supply

q

Porthole door not firmly closed

q

Water tap not turned on

q

Bent inlet hose

q

Sieve on inlet valve clogged

SUDS ESCAPING FROM DETERGENT DISPENSER TRAY.

q

Detergent used is not a washing machine detergent

q

Excessive detergent used

q

Drain Line is blocked

WATER LEAKAGE FROM THE MACHINE.

q

Inlet/Outlet hose connection loose

q

Fluff Filter not screwed on properly

q

Inlet hose leaking

q

Drain plug not fixed properly onto Drain hose.

MACHINE DOES NOT DRAIN.

q

Fluff Filter clogged

q

Outlet hose end above 1 mtr. from floor level

MACHINE VIBRATES STRONGLY DURING SPINNING.

q

Machine not levelled properly

q

Clothes not loaded as instructed

q

Water not drained completely

MACHINE DOES NOT START.

q

Check position of programme selector knob

q

Check water supply

q

Porthole door not closed properly

q

Indicator lamp not glowing

MACHINE DOES NOT SPIN.

q

Check if the Spin Cancel Button is pressed.

MOTOR NOISE

q

It is normal for noises to be heard while motor is running. However

wash load, belt tension and motor mounting bolt should be

checked for specified limits.

PUMP NOISE

q

It is normal for noises to be heard from the pump during the start-up

and final stage of draining. However check for fluff filter clogging.

21