Intel 80960HD User Manual

Page 86

Advertising
background image

80960HA/HD/HT

86

Datasheet

LOCKBAR

Output

BREQ

Output

A31

Output

A30

Output

A29

Output

A28

Output

A27

Output

A26

Output

A25

Output

A24

Output

A23

Output

A22

Output

A21

Output

A20

Output

A19

Output

A18

Output

A17

Output

A16

Output

Enable for A(31:0) and CT(3:0)

Control

A15

Output

A14

Output

A13

Output

A12

Output

A11

Output

A10

Output

A9

Output

A8

Output

A7

Output

A6

Output

A5

Output

A4

Output

A3

Output

A2

Output

NMIBAR

Input

Table 26. 80960Hx Boundary Scan Chain (Sheet 3 of 4)

#

Boundary Scan Cell

Cell Type

Comment

NOTES:

1. Cell#1 connects to TDO and cell #112 connects to TDI.
2. All outputs are tri-state.
3. In output and bidirectional signals, a logical 1 on the enable signal enables the output. A logical 0

tri-states the output.

Advertising
This manual is related to the following products: