For this, the calculations are:

Scanner offset

= X'7A6'

CICS stub length

= X'28'

Offset of CGT

= X'B8'

CGT base register = GPR 10

Offset within CGT = X'7A6' - X'28' - X'B8' = X'6C6' = 1734 (decimal)

MVC instruction looks like:

MVC

d(l,r),1734(10)

DFHEIV0

PGMLIT AT ...

To determine the EXEC CICS command:

1. Look at the Assembler-language for

MVC

d(l,r),1734(10)

DFHEIV0

PGMLIT AT ...

which occurs for the first MOVE

For the Scanner output:

CICS TRANSACTION AFFINITIES UTILITY

1995/11/19 Page

1

LOAD MODULE SCANNER - DETAILED LISTING OF CICS.PRODN1.LOCLLOAD

Module Name - ACCT04

/ Load Module Length - 000159D0 / Module Entry Point - 00000028

Offset

Storage Content (HEX)

EDF DEBUG Possible Command

Affinity

-------- -------------------------------------------------- --------- ----------------------- --------

000007A6 0A02E0000700004100

00669

WRITEQ TS

Trans

Total possible Affinity commands =

1

Total possible MVS POSTs

=

0

The COBOL source after translation was:

001123

001124

*EXEC CICS WRITEQ TS QUEUE('ACERLOG') FROM(ACCTERRO)

001125

*

LENGTH(ERR-LNG) END-EXEC.

001126

MOVE ' \

' 00669

' TO DFHEIV0

97800000 1057

001127

MOVE 'ACERLOG' TO DFHC0080

1034

001128

CALL 'DFHEI1' USING DFHEIV0 DFHC0080 ACCTERRO ERR-LNG.

EXT 1057 1034 380 861

The equivalent Assembler-language is:

001126 MOVE

002764 D210 8558 A6C6

MVC 1368(17,8),1734(10)

DFHEIV0

PGMLIT AT +1718

00276A 9240 8569

MVI 1385(8),X'40'

DFHEIV0+17

00276E D232 856A 8569

MVC 1386(51,8),1385(8)

DFHEIV0+18

DFHEIV0+17

001127 MOVE

002774 D207 8340 ACEA

MVC 832(8,8),3306(10)

DFHC0080

PGMLIT AT +3290

001128 CALL

00277A 4130 8558

LA

3,1368(0,8)

DFHEIV0

00277E 5030 D1B0

ST

3,432(0,13)

TS2=0

002782 4130 8340

LA

3,832(0,8)

DFHC0080

002786 5030 D1B4

ST

3,436(0,13)

TS2=4

00278A 4130 75A8

LA

3,1448(0,7)

ACCTERRO

00278E 5030 D1B8

ST

3,440(0,13)

TS2=8

002792 4130 9A0E

LA

3,2574(0,9)

ERR-LNG

002796 5030 D1BC

ST

3,444(0,13)

TS2=12

00279A 9680 D1BC

OI

444(13),X'80'

TS2=12

00279E 4110 D1B0

LA

1,432(0,13)

TS2=0

0027A2 4100 D150

LA

0,336(0,13)

CLLE@=2

0027A6 0530

BALR 3,0

0027A8 5030 D158

ST

3,344(0,13)

TGT FDMP/TEST-INFO. AREA +0

0027AC 58F0 A000

L

15,0(0,10)

V(DFHEI1 )

0027B0 05EF

BALR 14,15

0027B2 50F0 D078

ST

15,120(0,13)

TGTFIXD+120

0027B6 BF38 D089

ICM 3,8,137(13)

TGTFIXD+137

0027BA 0430

SPM 3,0

Figure 16. Example for finding an EXEC CICS command from the argument zero