SPACE FOR FIXING

The cooker can be close fitted below hotplate level. This requires a
minimum distance of 600mm between cupboard units of hotplate height.

When installing next to a tall cupboard, partition or wall, for a minimum
distance of 400mm above hotplate level, allow a side clearance of at least
65mm.

The diagram below illustrates the minimum clearance between the cooker
and adjacent walls, cupboards etc.

The wall behind the cooker between the hotplate and 450mm above, and
the width of the cooker, must be a non-combustible material such as
ceramic wall tiles.

If the cooker is to be fitted
close to a corner base unit on
the left hand side, ensure that
there is a clearance of at least
50mm to allow the oven door
to open fully for when
removing oven shelves.

COOKER HOODS

If a cooker hood is to be installed, refer to the cooker hood manufacturers’
instructions regarding fixing height.

UNPACKING THE COOKER

Unpack the components from inside the grill and oven: Check that the
following parts are present:
Grill pan and grid

Top oven shelf (1)

Pan supports (2)

Main oven shelves (2)

Enamelled burner caps (4)

Literature

Aluminium burner bodies (4)

65 mm Min

840 mm Min

400 mm Min

503 mm Min