Maintenance – Insignia 350TX User Manual

Page 31

Advertising
background image

29

1. Nothing happens when I turn the unit on.

Check the power cable connection at both ends. Be sure the cable is connected
correctly to a reliable power source—red lead to positive, black lead to negative
or ground. Ensure the power available at the mount is between 10 and 20 VDC.
If the unit is wired through a fuse panel, ensure the panel is powered. Often
accessory fuse panels are controlled by a separate switch or the ignition switch.
Also, often a fuse can appear to be good when in fact is not. Check the fuse
with a tester or replace it with a fuse known to be good.

Check the power connection to the 350TX. It is possible to force the power
cable connector into the cable holder incorrectly. If the connector is reversed, the
unit will not work. Examine the contacts on the back of the unit to ensure there
is no corrosion. Finally, ensure the unit is firmly seated on the mount. The
electrical contacts are not made until the unit is fully seated.

Ensure the metal cable retainer is properly installed in the mount. If not, the
power connected may push out when the unit is put on the mount.

2. There is no transducer detected.

The 350TX has the ability to detect and identify that a transducer is connected.
If, at power up, a message indicates “transducer not connected,” only simulator
operation is possible. First, ensure that an appropriate transducer connector is
positioned correctly in the connector holder, and that the unit is fully seated on
the mount. The 350TX will work with the standard tri-beam transducer.

Second, inspect the transducer cable from end to end for breaks, kinks, or cuts
in the outer casing of the cable. Also ensure the transducer is fully submerged
in water. If the transducer is connected to the unit through a switch, temporarily
connect it directly to the unit and try again. If none of these items identifies an
obvious problem, the transducer itself is probably the problem. Be sure to in-
clude the transducer if returning the unit for repair.

3. There is no bottom reading visible on the display.
There are a number of possible causes for this condition. If the loss of
bottom information occurs only at high boat speeds, the transducer needs
adjusting. If the digital depth readout is working but there is no bottom
visible on-screen, it is possible the depth range has been adjusted manually
to a range lower than what is needed to display the bottom. Also, in very
deep water, it may be necessary to manually increase the sensitivity setting
to maintain a graphic depiction of the bottom.

MAINTENANCE

TROUBLESHOOTING

Advertising