It is not necessary at the end of the operating
day to disrupt the TEMPERATURE setting in
order to turn the unit OFF. By switching the
POWER switch to OFF, the unit is no longer
operating. By switching the POWER switch to
ON when resuming operations, the cabinet
setting will be at the previous set point.

C2. FL2000 HIGH HUMIDITY HOLDING

MODULE

For Recommended Holding Temperatures,
see FL2000 guidelines on page 5.

When equipped with a high humidity module
your cabinet is designed to maintain the
temperature and moisture content of
prepared foods. The module has controls
for heat and humidity, a blower for air
circulation and a removable water bottle.
A POWER on/off switch is provided with a red
light to indicate when the unit is ON. Beside
the POWER switch are the TEMPERATURE
and HUMIDITY control knobs and yellow
lights to indicate when each element is on.
A seven foot, three wire, grounded cord is
supplied as part of the module.

1. With the POWER switch OFF, plug the cord

into a standard 20 amp, 125VAC grounded
receptacle on an individual branch circuit.
THE WATER BOTTLE SHOULD BE IN
PLACE PRIOR TO AND DURING MODULE
OPERATION. Push the bottle in until you hear
a click (indicating the valve half in the water
bottle has engaged the valve half in the
control panel).

2. To introduce humidity, fill the 2 gallon

capacity water bottle to the fill spout with
clean, cold tap water.

If you have hard tap

water, use distilled water in the bottle.

During

operation, check the water level every
several hours and refill as necessary. The
unit may be operated without water if
humidity is not desired. If humidity is not
required, turn the humidity knob to the OFF
position. There is no need to remove any
water from the bottle. During extended
periods of operation without humidity, the
bottle should be emptied of water. The next
time humidity is required, clean and rinse the
bottle and install it into the cabinet before
refilling with clean, cold water.

If the cabinet

is to be used for transporting food, empty the
water bottle first.

3. Push the POWER switch to the ON position

by depressing the top of the switch. The red
POWER lens in the switch will glow and the
blower will begin circulating air. The
thermometer display will show cabinet
temperature.

Note: This is not a foot

switch. Using it as a foot switch can damage
the switch and make the cabinet inoperable

.

4. The thermometer display shows the current

temperature in the cabinet. The temperature
setting can be adjusted by turning the

temperature knob clockwise to increase and
counter-clockwise to decrease temperature.

5. The humidity can be adjusted by turning the

humidity knob clockwise to increase and
counter-clockwise to decrease humidity. If
you wish to hold food without using humidity,
turn the Humidity control to MIN. This will
prevent the cabinet from introducing
additional humidity.

6. A buzzer alarm is located in the module to

indicate low water level. Refilling the bottle will
turn the buzzer off. If the bottle is not filled
promptly, the humidity will begin dropping off
in the cabinet. The bottle may be filled
through the pour spout. The maximum fill level
is to the fill opening. Turning the Humidity
knob to MIN will stop the buzzer until water
can be added. Then reset the humidity knob
to the desired position.

7. Allow the cabinet APPROXIMATELY 45 to 60

MINUTES to reach the desired settings.

THIS

IS A HOT FOOD HOLDING CABINET AND
IS NOT INTENDED TO RETHERMALIZE
COLD FOOD. MAKE SURE FOOD
AND CABINET ARE AT PROPER
TEMPERATURES BEFORE PLACING
FOOD IN THE CABINET.

NOTE:

The POWER switch red light will glow

as soon as the POWER switch is turned ON.
The yellow indicator light to the left of each
control knob will go on and off as controls
cycle the temperature and/or humidity
elements. The blower will operate as long as
the POWER switch is ON. If the yellow
indicator light for the temperature control
knob is not illuminated, this indicates that the
cabinet has achieved the set
TEMPERATURE. The light for the humidity
control knob will continue to cycle on and off
at a regular rate to maintain the desired
humidity. It is not necessary at the end of the
operating day to disrupt the TEMPERATURE
or HUMIDITY settings in order to turn the unit
OFF. By pushing the POWER switch to OFF,
the unit is no longer operating. By pushing
the POWER switch to ON when resuming
operations, the cabinet settings will be at the
previous settings.

8. The module can be removed for routine

cleaning. WHEN CLEANING, DO NOT
SPRAY OR POUR WATER ON THE MODULE
AND DO NOT IMMERSE THE MODULE IN
WATER. WIPE WITH A DAMP CLOTH AND
DRY WITH A TOWEL. Turn the module off
and remove the water bottle (this will allow
the humidity generator to drain), racks and
chimney. Remove the module from the
cabinet by lifting the front up enough to clear
the module slide detents, then pull the
module from the cabinet, grasping it with
both hands as it clears the cabinet. The cord
cannot be separated from the module, so be
careful when passing the cord through the
cabinet back panel.