62

9

OPTION INSTALLATIONS

Several IF filters are available for the IC-756. You can
install 2 filters for 9 MHz and 455 kHz IF. Choose ap-
propriate filter(s) for your operating needs.

9 MHz optional filters:
FL-100

CW NARROW FILTER

500 Hz/–6 dB

FL-101

CW NARROW FILTER

250 Hz/–6 dB

FL-223

SSB NARROW FILTER

1.9 kHz/–6 dB

FL-232

CW NARROW FILTER

350 Hz/–6 dB

455 kHz optional filters:
FL-52A

CW NARROW FILTER

500 Hz/–6 dB

FL-53A

CW NARROW FILTER

250 Hz/–6 dB

FL-222

SSB NARROW FILTER

1.8 kHz/–6 dB

FL-257

SSB WIDE FILTER

3.3 kHz/–6 dB

q

Remove the top and bottom covers as shown on
the opposite page.

w

Turn the transceiver upside down. Install the de-
sired filter as shown in the diagram at right.

• The 9 MHz filters can be installed in either direction.

e

Replace the top and bottom covers.

NOTE: After filter installation, specify the installed
filter using set mode. (p. 55) Otherwise, the in-
stalled filter will not function properly.

9 MHz optional filter

455 kHz optional filter

Optional IF filters

By installing the CR-502, the total frequency stability
of the transceiver will be improved.

q

Remove the top and bottom covers as shown on
the opposite page.

w

Turn the transceiver upside down. Remove 6
screws from the PLL shielding plate, then remove
the plate.

e

Cut the leads of R56 and L55 (in a shielded box)
on the PLL unit.

r

Put the CR-502 in the space available as shown in
the diagram, then solder its feet into place (6
points).

t

Adjust the reference frequency using a frequency
counter.

y

Return the shield case, shield plate and top/bottom
covers to their original positions.

CR-502 frequency stability: ± 0.5 ppm

(–30°C to +60°C;
–22°F to +140°F)

CR-502

CR-502

Solder

Cut

R56

L55

J81

Reference freq. check point
(cable from J81; 60.00 MHz)

CR-502

HIGH STABILITY CRYSTAL UNIT