Filter element servicing (cont.) – Intec STC SR00180SE User Manual

Page 10

Advertising
background image

INTEC 1206

SERIES-ICA-1

REVISION: B – 05/12/03

10 of 10

SECTION 4

Filter Element Servicing (cont.)

4.3.2 Inspection – Normal conditions.


At each 150 hours of operation or upon activation of the low inlet pressure warning light,
Remove the elements and inspect in accordance with paragraphs 4.3.1a, b, c and d.
Elements should be replaced after 1500 hours in service.

4.4

Oiling The Filter Element

CAUTION: Use only Oil, PN 40 – 10 or PN 40-10CW

AeroFilter oil is a compounded mineral based blend, formulated with special polymers to form
the tack barrier. A dye has been added to show where the oil has been applied. Eventually
the red color will fade but the oil will remain.


CAUTION: Never use the filter element without AeroFilter oil.

DO NOT use Engine Oil

DO NOT use Transmission Oil

DO NOT use Hydraulic Fluid

DO NOT use Lightweight Oils (WD 40, LPS, etc)



a) Fill sprayer with recommended quantity of Aerofilter oil (8 Fluid Ounces).
b) Charge sprayer with compressed air.
c) Apply oil to the filter element with smooth, complete passes parallel to pleats.
d) Repeat 90 degrees to pleats.
e) Use all of the measured quantity of oil.
f) Wait 30 minutes for proper wicking and lightly re-oil any light areas.

NOTE

Do not over-oil the element. Proper absorption is achieved when the filter media is
completely wicked and any surplus oil has been allowed to drip from the element.

The filter element is now ready for installation. Ref. Par. 4.2.


Advertising