Table 2-3 mode 1 drive addressing – IBM DCS9550 1S1 User Manual

Page 40

Advertising
background image

Installation

IBM System Storage DCS9550 1S1 Storage Expansion Unit Installation, Service, and User Guide

25

Notes

1 ON = switch to the left, OFF = switch to the right.

11

SOFT SELECT On

Selects functions using the
hardware switches

12

Not Used

Off

Table 2–2

Ops Panel Switch Functions (Default settings for DCS9550 1S1 Storage Expansion Unit

SCM usage at 1Gb/s)

Switch
Number

Function

Recommended
Setting

Definition

Table 2–3

Mode 1 Drive Addressing

Thumb
Wheel
Switch

Device Slot SEL_ID
Mode 1

0

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

NOTE:

Thumbwheel switch setting 0 causes a blinking amber LED indicating an invalid ID
condition; however, actual addressing is as stated.

1

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

2

16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

3

32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47

4

48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63

5

64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79

6

80 81 82 83 84 85 65 87 88 89 90 91 92 93 94 95

7

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

8

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

9

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

10

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

11

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

12

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

13

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

14

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111

15

96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111