SPECIFICATIONS

Tested in accordance with ISO3744 and in compliance with Directive 2000/14/EC

♦ Tested in accordance with ISO8662

Note:

Specifications are given at 90 psig (6.2 bar/620 kPa), the recommended Maximum Working Pressure of the tool.

90 psig (6.2 bar/620 kPa) is the recommended Maximum Working Pressure at the inlet of the tool when it is operating.

103 psig (7.1 bar/710 kPa) is the Maximum Pressure at the inlet of the tool when it is not operating.

SAVE THESE INSTRUCTIONS. DO NOT DESTROY.

When the life of the tool has expired, it is recommended that the tool be disassembled,

degreased and parts be separated by material so that they can be recycled.

Model

Shank Size Hex

w/ Collar

Weight

Air

Consumption

Impacts

per min.

Certified Sound

Power Level

Certified

Vibration Level

lbs (kg)

CFM @ 90 psi

dB (A)

m/s

2

IR90VRA

1-1/8” x 6”

88 (40)

64

960

112

7.94

IR90VRB

1-1/4” x 6”

88 (40)

64

960

112

7.94