Care and use – InSinkErator Chilled Water Tank & Cold Only Faucet CWT-00 User Manual

Page 11

Advertising
background image

Electric Shock Hazard: To prevent electrical shock, disconnect power before
servicing unit. Use only a properly grounded and polarized electric outlet.

Replace filter cartridge when there is an obvious
decrease in water flow to the faucet or if there is an
objectionable taste or odor to the water.

When the inlet and outlet ports have been closed

and the filter’s internal pressure has been relieved,
water (about 2 oz) will discharge from vent line.

If the new filter cartridge cannot be inserted,

insert the old one and turn until it stops, remove it
and then retry the new cartridge.

Carbon filters should be replaced within 12 months.

Filter replacement instructions:

Replace with an InSinkErator

®

filter.

Place pan or dish towel under the filter to
catch water drainage during change.

Slowly turn the cartridge counter-clockwise
completely until it stops (1/4 turn).

Pull cartridge straight down and discard.

Insert new cartridge into filter head.

Top surface of cartridge will become flush
with the bottom of the filter head when
fully engaged.

Turn the cartridge clockwise until it stops
(1/4 turn).

Align the in/out arrow on the head and
bracket assembly to the in/out arrow on
the cartridge.

Open faucet to expel trapped air.

Run water for 3 minutes before usage.

The temperature on the chilled
water tank is controlled by the
temperature control knob
on the front of the unit.

For colder water
Turn the control knob
clockwise. Allow 60 mins.

For less cold water
Turn the control knob counterclockwise.

To shut down the chilled water tank –
Turn control knob counterclockwise
to the “OFF” position.

Regularly inspect the unit for any signs of
leakage. If there are signs of water damage,
immediately remove the unit from service.

To avoid water damage from leakage,
replace all cut, loose or split tubing.

A drain pan, plumbed to an appropriate
drain or outfitted with a leak detector,
should be used in those applications where
any leakage could cause property damage.

PROPERTY DAMAGE

CARE AND USE

Only use mild cleaners to clean the faucet
and plastic components.

Cleaners with acids, abrasives, alkaline or
organic solvents will result in deterioration of
the plastic components and void the warranty.

CLEANING THE TANK AND FAUCET

Anytime the chilled water tank will not be used for an
extended period, or if temperature is below freezing,
unplug and drain the unit.

Disconnect power from unit.

Shut the cold water supply off at the valve.

Open cold only faucet to relieve pressure
from the chilled water tank.

Disconnect the inlet/outlet water lines
attached to the chilled water tank.

Drain water from the chilled water tank by
tipping it on its left side (power cord side)
and allow water to run into a large container.

Once drained, set unit in its normal
upright position for storage.

To put the chilled water tank back into
service, reconnect the water lines (see
Pages 4-7) and open the water supply.

Open the cold water faucet until water
runs from the faucet.

Plug in the unit and set control knob to
desired temperature.

SEASONAL STORAGE/DRAINAGE

FILTER GUIDE AND REPLACEMENT

(Filtration available as an option)

ADJUSTING WATER TEMPERATURE

C

old

er w

ater

11

Advertising