Measurement Characteristics
Accuracy is

±

(% reading + number of digits) at 23

°

C

±

5

°

C, less than 80% R.H.


DC Volts

Range

Resolution

Accuracy

Over voltage

protection

600.0mV 100µV

6.000V

1mV

60.00V

10mV

600.0V

100mV

1000V

1V

±(0.5% + 2dgt)

1000V rms


AC Volts

Range

Resolution

Accuracy

Over voltage

protection

600.0mV 100µV

Unspecified

6.000V

1mV

60.00V

10mV

600.0V

100mV

750V

1V

±(0.9% + 5dgt)

50Hz ~ 500Hz

*

1000V rms

Input Impedance: 10MΩ // less than 100pF.
CMRR / NMRR: (Common Mode Rejection Ratio)
(Normal Mode Rejection Ratio)
V

AC

: CMRR > 60dB at DC, 50Hz / 60Hz

V

DC

: CMRR > 100dB at DC, 50Hz / 60Hz

NMRR > 50dB at DC, 50Hz / 60Hz
AC Conversion Type: 61-320: Average sensing rms indication.
61-322 / 61-324:
AC conversions are ac-coupled, true rms responding, calibrated to
the sine wave input.
* The basic accuracy is specified for sine wave below 4000 counts. Over 4000 counts, need to add 0.6% to the
accuracy for non-sine waves below 2000 counts, refer to the following for accuracy:
Crest Factor (C.F.):
+1.5% addition error for C.F. from 1.4 to 3
+3.0% addition error for C.F. from 3 to 4 where C.F.=Peak / RMS