Intel SGI Altix 450 User Manual

Page 84

Advertising
background image

Select a device: [1-1 or 0 to quit] 1

1. Identify firmware, BIOS, and/or FCode

2. Download firmware (update the FLASH)

4. Download/erase BIOS and/or FCode (update the FLASH)

8. Scan for devices

10. Change IOC settings (interrupt coalescing)

13. Change SAS IO Unit settings

16. Display attached devices

18. Change WWID

20. Diagnostics

21. RAID actions

22. Reset bus

23. Reset target

24. Clear ACA

39. Force firmware download boot

45. Concatenate SAS firmware and NVDATA files

60. Show non-default settings

61. Restore default settings

97. Reset SAS phy

98. Reset SAS link

99. Reset port

e Enable expert mode in menus

p Enable paged mode in menus

w Enable logging

Main menu, select an option: [1-99 or e/p/w or 0 to quit] 8

Important: After this command is entered, the load device cannot be accessed again to open files
until lsiutil has been exited and restarted.

SAS1068's links are 3.0 G, 3.0 G, down, down, down, down, down, down

B___T___L Type Vendor Product Rev SASAddress PhyNum

0 0 0 Disk SGI ST3146854SS X422 5000c5000002cb45 0

0 1 0 Disk SGI ST3146854SS X422 5000c500000121cd 1

Main menu, select an option: [1-99 or e/p/w or 0 to quit] 0

Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC

1. 01/00/01/0 LSI Logic SAS1068 B0 105 01100000 0

Select a device: [1-1 or 0 to quit] 1

Advertising