Installation – Indesit 50 CM FREE STANDING COOKER KD3G User Manual

Page 4

Advertising
background image

GB

3

The appliance must only be installed by a

competent person. In the UK, CORGI registered

installers undertake to work to safe and

satisfactory standards.

Before moving your cooker check that it is cool, and

switch off at the cooker control unit. Movement of

your cooker is most easily achieved by lifting the

front as follows:

Open the grill door sufficiently to allow a comfortable

grip on the underside front edge of the oven roof,

avoiding any grill elements.

 Take care in moving the

cooker as it is heavy. Take

care to ensure that any floor

covering is not damaged. (see

figure)

Splashplate optional, apply to

Parts Department (see Back

Cover for contact number.)

The following instructions should be read by a

qualified technician to ensure that the appliance is

installed, regulated and technically serviced

correctly in compliance with current regulations.

 remember to unplug the appliance from the

mains before regulating the appliance or carrying

out any maintenance work.

Positioning

 this unit may be installed and used only in

permanently ventilated rooms according to the

British Standards Codes Of Practice: B.S. 6172/B.S.

5440, Par. 2 and B.S. 6891 Current Editions. The

following requirements must be observed:

a. The cooker should not be installed in a bed sitting

room with a volume of less than 20m

3

. If it is

installed in a room of volume less than 5m

3

an air

vent of effective area of 110cm

2

is required, if it is

installed in a room of volume between 5m

3

and

10m

3

a supplementary airvent area of 50cm2 is

required, if the volume exceeds 11m

3

no airvent is

required. However, if the room has a door or a

window which opens directly to the outside no air

vent is required even when the volume is between

5m

3

and 11m

3

.

b. During prolonged use of the appliance you may

consider it necessary to open a window to the

outside to improve ventilation.

c. If there are other fuel burning appliances in the

same room, B.S.5440 Part 2 Current Edition,

should, be consulted to determine the requisite air

vent feet in the plinth (900mm - 915mm). Adjust

the feet by tilting the cooker from the side. Then

install the product into position.

 This appliance must not be fitted on a platform.

The cooker is designed to fit between kitchen

cabinets spaced 500mm apart. The space either

side need only be sufficient to allow withdrawal of

the cooker for servicing. It can be used with

cabinets one side or both as well as in a corner

setting. It can also be used free-standing.

Adjacent side walls which project above hob level,

must not be nearer to the cooker than 150mm or

65mm (Fig. A) and should be protected by heat

resistant material. Any overhanging surface or

cooker hood should not be nearer than 750mm.

(Fig.A)

a .The cooker may be located in a kitchen, a

diner or bed sitting room, but not in a bathroom or

shower room.

b .The hoods must be installed according to the

requirements in the hood handbook.

c .The wall in contact with the back of the cooker

must be of flameproof material.

d .The cooker is fitted with a safety chain that must

be attached to a hook, secured to the wall behind

the appliance.

 some models can have their gas connection

inverted. It is important to make sure the safety

chain is always situated on the side which

corresponds to the hose holder (Fig. B).

65 mm min

500 mm min

400 mm min

400 mm min

750 mm min

Tall cupboard on the left hand
side of 50cm gas cooker

65 mm min

65 mm min

150 mm min

500 mm min

750 mm min

Tall cupboard on the right hand
side of 50cm gas cooker

Fig. A

Fig. B

Installation

Moving the Cooker

Advertising