English – Intel GA-8I955X ROYAL User Manual

Page 69

Advertising
background image

Appendix

- 69 -

English

4-1-4 Serial ATA BIOS Setting Utility Introduction

RAID Levels

RAID (Redundant Array of Independent Disks) is a method of combining two hard disk drives into one logical
unit. The advantage of an Array is to provide better performance or data fault tolerance. Fault tolerance is
achieved through data redundant operation, where if one drives fails, a mirrored copy of the data can be
found on another drive. This can prevent data loss if the operating system fails or hangs. The individual disk
drives in an array are called members. The configuration information of each member is recorded in the
reserved sector that identifies the drive as a member. All disk members in a formed disk array are recognized
as a single physical drive to the operating system.
Hard disk drives can be combined together through a few different methods. The different methods are
referred to as different RAID levels. Different RAID levels represent different performance levels, security
levels and implementation costs. The RAID levels which the Intel

®

ICH7R chipset supports are RAID 0

, RAID 1, RAID 0+1, and RAID 5.

RAID 0 (Striping)
RAID 0 reads and writes sectors of data interleaved between multiple drives. If any disk member fails, it
affects the entire array. The disk array data capacity is equal to the number of drive members times the
capacity of the smallest member. The Intel RAID striping block size can be set from 4KB to 64KB. RAID
0 does not support fault tolerance.

RAID 1 (Mirroring)
RAID 1 writes duplicate data onto a pair of drives and reads both sets of data in parallel. If one of the
mirrored drives suffers a mechanical failure or does not respond, the remaining drive will continue to function.
Due to redundancy, the drive capacity of the array is the capacity of the smallest drive. Under a RAID 1
setup, an extra drive called the spare drive can be attached. Such a drive will be activated to replace a failed
drive that is part of a mirrored array. Due to the fault tolerance, if any RAID 1 drive fails, data access will not
be affected as long as there are other working drives in the array.

RAID 0+1 (Striping + Mirroring)
RAID 0+1 combines the performance of data striping (RAID 0) and the fault tolerance of disk mirroring
(RAID 1). Data is striped across multiple drives and duplicated on another set of drives.

RAID 5 (Striping with Parity)
RAID 5 provides good fault tolerance and allows for overlapped I/O operations. Under a RAID 5 setup,
data and parity information are equally distributed to each disk member in the array. If any one of the
drives fails, the remaining drive will continue to function. After replacing the failed drive, you can rebuild
the data from the remaining data and parity. Only one drive can be safely crash without any data loss.

Advertising
This manual is related to the following products: