IBM 6648 User Manual

Page 172

Advertising
background image

POST Error Code

FRU/Action

1107

1.

Serial Device Cable

2.

System Board

1110

Register test failed

1.

Run Enhanced Diagnostics

2.

System Board

1116

Interrupt error

1.

Run Enhanced Diagnostics

1117

Failed baud rate test

1.

Run Enhanced Diagnostics

1162

Serial port configuration error

1.

Run Configuration

2.

Serial Adapter
(if installed)

3.

System Board

11XX

Not listed above

1.

System Board

1201

1.

System Board

2.

Any Serial Device

1202, 1206, 1208, 1209, 12XX

1.

Dual Async Adapter/A

2.

System Board

3.

Any Serial Device

1207

1.

Communications Cable

2.

Dual Async Adapter/A

13XX

1.

Game Adapter

1402

Printer not ready

Information only

1403

No paper error, or interrupt failure

Information only

1404

System board timeout failure

1.

Run Enhanced Diagnostics

1405

Parallel adapter error

1.

Run Enhanced Diagnostics

1406

Presence test error

1.

Run Enhanced Diagnostics

14XX

Not listed above. Check printer before

replacing system board

1.

Printer

2.

System Board

15XX

1.

SDLC Adapter

1692

Boot sequence error

1.

Run FDISK to ensure at least one active
partition is set active

16XX

1.

36/38 Workstation Adapter

1762

Hard disk drive configuration error

1.

Run Configuration. (See “Setup Utility
program” on page 122.)

158

Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Advertising
This manual is related to the following products: