GRF Configuration Files

271

# [mode=SDH|SONET] [clock=Ext|Int]

#

# The ’card’ and ’connector’ specification are mandatory.

#

# The card should be identified by a hexidecimal digit representing

# the slot number of the card in the GigaRouter chassis.

#

# The connector should be either ’top’ or ’bottom’.

#

# The ’protocol’ parameter defines the signalling protocol to be used

# in the setup of Switched Virtual Circuits (SVC’s) on this physical

# interface. This parameter is optional. If left unspecified, the

# ATM card uses UNI3.0 signalling by default.

#

# Valid values for the signalling parameter include:

#

# UNI3.0 - for the UNI 3.0 signalling protocol.

#

# UNI3.1 - for the UNI 3.1 signalling protocol.

#

# NONE - for no signalling protocol.

#

# The ’mode’ specification is optional. It can be either SDH or SONET.

# By default, it uses SONET.

#

# The ’clock’ specification is also optional. It can be either Ext(ernal)

# or Int(ernal). The default setting is Internal clocking.

#

#Signalling card=9 connector=top protocol=UNI3.1

#Signalling card=9 connector=bottom protocol=NONE

#Signalling card=a connector=top protocol=UNI3.1

#Signalling card=a connector=bottom protocol=NONE

#

# Interfaces

#

# Lines beginning with the keyword "Interface" define

# GigaRouter logical ATM interfaces.

#

# The format of a logical interface definition is:

#

# Interface ifname [service=service_name] [traffic_shape=shape_name] \

# [bridge_method=method[,restriction]]

#

# The optional ’service’ parameter allows an ATM service to be

# be defined for this logical interface (the ’service_name’ must be

# a name defined in the Services section above).

#

# The optional ’traffic_shape’ parameter allows a traffic shape

# to be defined for this logical interface (the ’shape_name’ must be

# a named defined as a Traffic_Shape above).

#

# If no traffic shape is specified, a default shape of 155Kbps, high

# quality of service is used.

#

# The optional ’bridge_method’ parameter allows an interface to be used

# for RFC 1483 bridging. The valid values for the bridge_method parameter

# are:

#

# llc_encapsulated - Use a single PVC, with each frame

# encapsulated with an LLC header to identify

Advertising