Impulse DO4837R User Manual

Page 7

Advertising
background image

R

888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com

VENTING INSTRUCTIONS FOR AIR INTAKE / EXHAUST - DO4837R

7

BACK VIEW OF CABINET

AFTER POSITIONED ON

CUSTOMER-SUPPLIED COUNTER/BASE

15”

MINIMUM

AIR

EXHAUST

SPACE

9 1/2”

19” MINIMUM

AIR EXHAUST

SPACE

45” MINIMUM MAINTENANCE

ACCESS SPACE

25” MINIMUM AIR

INTAKE SPACE

9 1/2”

FACIA ENCLOSURE

13”

MINIMUM

AIR INTAKE

SPACE

Warning: The minimum intake and exhaust areas must be allowed (as illustrated

below) or case temperatures may fluctuate beyond safe parameters.

15” MINIMUM

MAINTENANCE

ACCESS SPACE

2”

NOTES:
1. BACK OF CABINET MUST BE VENTED A MINIMUM OF 13” x 25” FOR AIR INTAKE.
2. BACK OF CABINET MUST BE VENTED A MINIMUM OF 19” x 21” FOR AIR EXHAUST.
3. BACK OF CABINET MUST PROVIDE A MINIMUM OF 15” x 45” FOR MAINTENANCE ACCESS. THIS AREA

(AS DIMENSIONED BELOW) WILL ALLOW SERVICE TO SLIDE OUT CONDENSING UNIT.

4. SEE REFRIGERATION FUNDAMENTALS FOR VIEW OF CONDENSING UNIT AFTER SLIDE-OUT.

5. AIR

INTAKE

(ILLUSTRATED
BELOW).

6.

AIR EXHAUST
(ILLUSTRATED
BELOW).